Skip to main content

Wp 6070 Wvps Firmware CVE-2023-37856

MEDIUM
Externally Controlled Reference to a Resource in Another Sphere (CWE-610)
2023-08-09 info@cert.vde.com
4.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
4.3 MEDIUM
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Aug 09, 2023 - 07:15 nvd
MEDIUM 4.3

DescriptionNVD

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges is able to gain limited read-access to the device-filesystem through a configuration dialog within the embedded Qt browser .

AnalysisAI

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges is able to gain limited read-access to the device-filesystem through a configuration. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-610. In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges is able to gain limited read-access to the device-filesystem through a configuration dialog within the embedded Qt browser . Affected products include: Phoenixcontact Wp 6070-Wvps Firmware, Phoenixcontact Wp 6101-Wxps Firmware, Phoenixcontact Wp 6121-Wxps Firmware, Phoenixcontact Wp 6156-Whps Firmware, Phoenixcontact Wp 6185-Whps Firmware. Version information: prior to 4.0.10.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2023-3572 CRITICAL
10.0 Aug 08

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote, unauthenticated attacker may use an

CVE-2023-37861 HIGH
8.8 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 an authenticated remote attacker can execute c

CVE-2023-3573 HIGH
8.8 Aug 08

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges may use

CVE-2023-3571 HIGH
8.8 Aug 08

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges may use

CVE-2023-3570 HIGH
8.8 Aug 08

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges may use

CVE-2023-37862 HIGH
8.2 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 an unauthenticated remote attacker can access

CVE-2023-37860 HIGH
7.5 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote unauthenticated attacker can obtain t

CVE-2023-37864 HIGH
7.2 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with SNMPv2 write privileges

CVE-2023-37863 HIGH
7.2 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with SNMPv2 write privileges

CVE-2023-37859 HIGH
7.2 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 the SNMP daemon is running with root privilege

CVE-2023-37857 HIGH
7.2 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 an authenticated, remote attacker with admin p

CVE-2023-37858 MEDIUM
4.9 Aug 09

In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 an authenticated, remote attacker with admin p

Share

CVE-2023-37856 vulnerability details – vuln.today