Stationguard
CVE-2023-28611
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Authorization logic validation
MITRE ATT&CK
1 technique across 1 tactic: Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could bypass authorization checks to access restricted resources by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and test authorization logic, implement consistent access control checks, use centralized authorization framework.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Incorrect Authorization (CWE-863), which allows attackers to bypass authorization checks to access restricted resources. Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions. Affected products include: Omicronenergy Stationguard, Omicronenergy Stationscout. Version information: through 2.20.
Know when Stationguard gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Affected Products (CPE)NVD
More in Stationguard
View allThe update process in OMICRON StationGuard and OMICRON StationScout before 2.21 can be exploited by providing a modified
OMICRON StationGuard before 1.10 allows remote attackers to cause a denial of service (connectivity outage) via crafted
NVD
CVE.org
EPSS
GitHub PoC