Nexpose
CVE-2023-1699
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability. This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187.
AnalysisAI
Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-425. Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability. This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187. Affected products include: Rapid7 Nexpose. Version information: version 6.6.187..
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Versions of Nexpose prior to 6.4.66 fail to adequately validate the source of HTTP requests intended for the Automated A
Cross-site request forgery (CSRF) vulnerability in Rapid7 Nexpose Security Console before 5.5.4 allows remote attackers
Rapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents.
Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search opera
A Cross-Site Request Forgery (CSRF) vulnerability was found in Rapid7 Nexpose InsightVM Security Console versions 6.5.0
Rapid7 Nexpose versions 6.5.50 and prior suffer from insufficient session expiration when an administrator performs a se
The default SSH configuration in Rapid7 Nexpose hardware appliances shipped before June 2017 does not specify desired al
A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low p
All editions of Rapid7 Nexpose installers prior to version 6.4.24 contain a DLL preloading vulnerability, wherein it is
In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in t
The Java keystore in all versions and editions of Rapid7 Nexpose prior to 6.4.50 is encrypted with a static password of
Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the loc
Same weakness CWE-425 – Direct Request ('Forced Browsing')
View allSame technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today