Ecostruxure Geo Scada Expert 2019
CVE-2023-0595
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A09:2025 - Security Logging & Alerting Failures
ASVS 5.0
V16 - Security Logging and Error Handling Log output neutralization
|
| Impact | CVSS score of 5.3 (MEDIUM). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-117. A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions) Affected products include: Schneider-Electric Clearscada, Schneider-Electric Ecostruxure Geo Scada Expert 2019, Schneider-Electric Ecostruxure Geo Scada Expert 2020, Schneider-Electric Ecostruxure Geo Scada Expert 2021.
Know when Ecostruxure Geo Scada Expert 2019 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original rele
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server
Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxu
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB