Basic Pdu Firmware CVE-2022-33174

HIGH
Incorrect Authorization (CWE-863)
2022-06-13 cve@mitre.org
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Jun 13, 2022 - 18:15 nvd
HIGH 7.5

DescriptionNVD

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.

AnalysisAI

Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Incorrect Authorization (CWE-863), which allows attackers to bypass authorization checks to access restricted resources. Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext. Affected products include: Powertekpdus Basic Pdu Firmware, Powertekpdus Pm Pdu Firmware, Powertekpdus Piml Pdu Firmware, Powertekpdus Smart Pim Firmware, Powertekpdus Smart Pos Firmware. Version information: before 3.30.30.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and test authorization logic, implement consistent access control checks, use centralized authorization framework.