Skip to main content

Bently Nevada 3701 40 Firmware CVE-2022-29952

CRITICAL
Missing Authentication for Critical Function (CWE-306)
2022-07-26 cve@mitre.org
9.1
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.1 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jul 26, 2022 - 22:15 nvd
CRITICAL 9.1

DescriptionNVD

Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

AnalysisAI

Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. Affected products include: Bakerhughes Bently Nevada 3701\/40 Firmware, Bakerhughes Bently Nevada 3701\/44 Firmware, Bakerhughes Bently Nevada 3701\/46 Firmware, Bakerhughes Bently Nevada 60M100 Firmware. Version information: through 2022.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Require authentication for all sensitive operations, implement defense in depth.

Share

CVE-2022-29952 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy