Baxter
CVE-2022-26393
HIGH
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
1DescriptionNVD
The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a Denial of Service (DoS) on the WBM.
AnalysisAI
The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-134. The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a Denial of Service (DoS) on the WBM. Affected products include: Baxter Spectrum Wireless Battery Module Firmware, Baxter Sigma Spectrum 35700Bax Firmware, Baxter Sigma Spectrum 35700Bax2 Firmware, Baxter Baxter Spectrum Iq 35700Bax3 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an un
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. Rated criti
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP servic
Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BA
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensit
In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that c
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensi
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit
Same weakness CWE-134 – Use of Externally-Controlled Format String
View allSame technique Denial Of Service