Inet 900 Firmware
CVE-2022-24120
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V14 - Data Protection Encrypted storage of sensitive data
|
| Impact | CVSS score of 4.6 (MEDIUM). Attack characteristics: physical attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Certain General Electric Renewable Energy products store cleartext credentials in flash memory. Rated medium severity (CVSS 4.6), this vulnerability is no authentication required, low attack complexity.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-312. Certain General Electric Renewable Energy products store cleartext credentials in flash memory. This affects iNET and iNET II before 8.3.0. Affected products include: Ge Inet 900 Firmware, Ge Inet Ii 900 Firmware, Ge Sd1 Firmware, Ge Sd2 Firmware, Ge Sd4 Firmware. Version information: before 8.3.0..
Severity by source
AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Certain General Electric Renewable Energy products store cleartext credentials in flash memory. This affects iNET and iNET II before 8.3.0.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
More in Inet 900 Firmware
View allCertain General Electric Renewable Energy products have a hidden feature for unauthenticated remote access to the device
Certain General Electric Renewable Energy products download firmware without an integrity check. Rated critical severity
Certain General Electric Renewable Energy products have inadequate encryption strength. Rated critical severity (CVSS 9.
Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory de
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB