Skip to main content

Logo Cmr2020 Firmware CVE-2021-37186

MEDIUM
Use of Insufficiently Random Values (CWE-330)
2021-09-14 productcert@siemens.com
5.4
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
5.4 MEDIUM
AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Sep 14, 2021 - 11:15 nvd
MEDIUM 5.4

DescriptionNVD

A vulnerability has been identified in LOGO! CMR2020 (All versions < V2.2), LOGO! CMR2040 (All versions < V2.2), SIMATIC RTU3010C (All versions < V4.0.9), SIMATIC RTU3030C (All versions < V4.0.9), SIMATIC RTU3031C (All versions < V4.0.9), SIMATIC RTU3041C (All versions < V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information.

AnalysisAI

A vulnerability has been identified in LOGO!. Rated medium severity (CVSS 5.4), this vulnerability is no authentication required, low attack complexity.

Technical ContextAI

This vulnerability is classified under CWE-330. A vulnerability has been identified in LOGO! CMR2020 (All versions < V2.2), LOGO! CMR2040 (All versions < V2.2), SIMATIC RTU3010C (All versions < V4.0.9), SIMATIC RTU3030C (All versions < V4.0.9), SIMATIC RTU3031C (All versions < V4.0.9), SIMATIC RTU3041C (All versions < V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information. Affected products include: Siemens Logo\! Cmr2020 Firmware, Siemens Logo\! Cmr2040 Firmware, Siemens Simatic Rtu3010C Firmware, Siemens Simatic Rtu3030C Firmware, Siemens Simatic Rtu3031C Firmware.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.