Skip to main content

Visionary S Cx Firmware CVE-2021-32496

MEDIUM
Inadequate Encryption Strength (CWE-326)
2021-06-28 psirt@sick.de
5.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
5.3 MEDIUM
AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack Vector
Network
Attack Complexity
High
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Jun 28, 2021 - 12:15 nvd
MEDIUM 5.3

DescriptionNVD

SICK Visionary-S CX up version 5.21.2.29154R are vulnerable to an Inadequate Encryption Strength vulnerability concerning the internal SSH interface solely used by SICK for recovering returned devices. The use of weak ciphers make it easier for an attacker to break the security that protects information transmitted from the client to the SSH server, assuming the attacker has access to the network on which the device is connected. This can increase the risk that encryption will be compromised, leading to the exposure of sensitive user information and man-in-the-middle attacks.

AnalysisAI

SICK Visionary-S CX up version 5.21.2.29154R are vulnerable to an Inadequate Encryption Strength vulnerability concerning the internal SSH interface solely used by SICK for recovering returned. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-326. SICK Visionary-S CX up version 5.21.2.29154R are vulnerable to an Inadequate Encryption Strength vulnerability concerning the internal SSH interface solely used by SICK for recovering returned devices. The use of weak ciphers make it easier for an attacker to break the security that protects information transmitted from the client to the SSH server, assuming the attacker has access to the network on which the device is connected. This can increase the risk that encryption will be compromised, leading to the exposure of sensitive user information and man-in-the-middle attacks. Affected products include: Sick Visionary-S Cx Firmware. Version information: version 5.21.2.29154.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2021-32496 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy