By executing a special command, an user with administrative rights can get access to extended debug functionality on the VRM allowing an impact on integrity or availability of the installed software. This issue also affects installations of the DIVAR IP and BVMS with VRM installed.
AnalysisAI
By executing a special command, an user with administrative rights can get access to extended debug functionality on the VRM allowing an impact on integrity or availability of the installed software. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-489. By executing a special command, an user with administrative rights can get access to extended debug functionality on the VRM allowing an impact on integrity or availability of the installed software. This issue also affects installations of the DIVAR IP and BVMS with VRM installed. Affected products include: Bosch Bosch Video Management System, Bosch Video Recording Manager.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Video Recording Manager
View allA recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DI
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthentica
An unauthenticated attacker is able to send a special HTTP request, that causes a service to crash. Rated high severity
A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in
A Path Traversal vulnerability located in the webserver affects several Bosch hardware and software products. Rated medi
An error in a page handler of the VRM may lead to a reflected cross site scripting (XSS) in the web-based interface. Rat
An Open Redirect vulnerability located in the webserver affects several Bosch hardware and software products. Rated medi
Same weakness CWE-489 – Active Debug Code
View allSame technique Information Disclosure