Installbuilder
CVE-2021-22037
HIGH
Severity by source
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Under certain circumstances, when manipulating the Windows registry, InstallBuilder uses the reg.exe system command. The full path to the command is not enforced, which results in a search in the search path until a binary can be identified. This makes the installer/uninstaller vulnerable to Path Interception by Search Order Hijacking, potentially allowing an attacker to plant a malicious reg.exe command so it takes precedence over the system command. The vulnerability only affects Windows installers.
AnalysisAI
Under certain circumstances, when manipulating the Windows registry, InstallBuilder uses the reg.exe system command. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-427. Under certain circumstances, when manipulating the Windows registry, InstallBuilder uses the reg.exe system command. The full path to the command is not enforced, which results in a search in the search path until a binary can be identified. This makes the installer/uninstaller vulnerable to Path Interception by Search Order Hijacking, potentially allowing an attacker to plant a malicious reg.exe command so it takes precedence over the system command. The vulnerability only affects Windows installers. Affected products include: Vmware Installbuilder.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Installbuilder
View allOn Windows, the uninstaller binary copies itself to a fixed temporary location, which is then executed (the originally c
InstallBuilder for Qt Windows (versions prior to 20.7.0) installers look for plugins at a predictable location at initia
Windows binaries generated with InstallBuilder versions earlier than 19.7.0 are vulnerable to tampering even if they con
InstallBuilder AutoUpdate tool and regular installers enabling <checkForUpdates> built with versions earlier than 19.11
InstallBuilder Qt installers built with versions previous to 22.10 try to load DLLs from the installer binary parent dir
Same weakness CWE-427 – Uncontrolled Search Path Element
View allSame technique Information Disclosure
View allShare
External POC / Exploit Code