Skip to main content

Broadworks Application Server CVE-2021-1562

MEDIUM
Information Exposure (CWE-200)
2021-07-08 psirt@cisco.com
4.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
4.3 MEDIUM
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Jul 08, 2021 - 19:15 nvd
MEDIUM 4.3

DescriptionNVD

A vulnerability in the XSI-Actions interface of Cisco BroadWorks Application Server could allow an authenticated, remote attacker to access sensitive information on an affected system. This vulnerability is due to improper input validation and authorization of specific commands that a user can execute within the XSI-Actions interface. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a specific set of commands. A successful exploit could allow the attacker to join a Call Center instance and have calls that they do not have permissions to access distributed to them from the Call Center queue. At the time of publication, Cisco had not released updates that address this vulnerability for Cisco BroadWorks Application Server. However, firmware patches are available.

AnalysisAI

A vulnerability in the XSI-Actions interface of Cisco BroadWorks Application Server could allow an authenticated, remote attacker to access sensitive information on an affected system. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. A vulnerability in the XSI-Actions interface of Cisco BroadWorks Application Server could allow an authenticated, remote attacker to access sensitive information on an affected system. This vulnerability is due to improper input validation and authorization of specific commands that a user can execute within the XSI-Actions interface. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a specific set of commands. A successful exploit could allow the attacker to join a Call Center instance and have calls that they do not have permissions to access distributed to them from the Call Center queue. At the time of publication, Cisco had not released updates that address this vulnerability for Cisco BroadWorks Application Server. However, firmware patches are available. Affected products include: Cisco Broadworks Application Server.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.

Share

CVE-2021-1562 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy