Skip to main content

Melsec Iq Rj71Eip91 Firmware CVE-2020-5656

CRITICAL
2020-11-02 vultures@jpcert.or.jp
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Nov 02, 2020 - 21:15 nvd
CRITICAL 9.8

DescriptionNVD

Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.

AnalysisAI

Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

Improper access control vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Affected products include: Mitsubishielectric Melsec Iq-Rj71Eip91 Firmware, Mitsubishielectric Melsec Iq-Rj71Pn92 Firmware, Mitsubishielectric Melsec Iq-Rd81Dl96 Firmware, Mitsubishielectric Melsec Iq-Rd81Mes96N Firmware, Mitsubishielectric Melsec Iq-Rd81Opc96 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2020-5656 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy