Forerunner 235 Firmware
CVE-2020-27485
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V2 - Validation and Business Logic Array index validation
|
| Impact | CVSS score of 9.9 (CRITICAL). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the critical-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Garmin Forerunner 235 before 8.20 is affected by: Array index error. Rated critical severity (CVSS 9.9), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-129. Garmin Forerunner 235 before 8.20 is affected by: Array index error. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check the index provided when accessing the local variable in the LGETV and LPUTV instructions. This provides the ability to both read and write memory outside the bounds of the TVM context allocation. It can be leveraged to construct a use-after-free scenario, leading to a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment. Affected products include: Garmin Forerunner 235 Firmware. Version information: before 8.20.
Know when Forerunner 235 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Garmin Forerunner 235 before 8.20 is affected by: Array index error. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check the index provided when accessing the local variable in the LGETV and LPUTV instructions. This provides the ability to both read and write memory outside the bounds of the TVM context allocation. It can be leveraged to construct a use-after-free scenario, leading to a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
More in Forerunner 235 Firmware
View allGarmin Forerunner 235 before 8.20 is affected by: Buffer Overflow. Rated critical severity (CVSS 9.9), this vulnerabilit
Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. Rated critical severity (CVSS 9.9), this vulnerabili
Garmin Forerunner 235 before 8.20 is affected by: Array index error. Rated critical severity (CVSS 9.9), this vulnerabil
NVD
CVE.org
EPSS
GitHub
Exploit-DB