1DescriptionCVE.org
When configuring stateless firewall filters in Juniper Networks EX4600 and QFX 5000 Series devices using Virtual Extensible LAN protocol (VXLAN), the discard action will fail to discard traffic under certain conditions. Given a firewall filter configuration similar to: family ethernet-switching { filter L2-VLAN { term ALLOW { from { user-vlan-id 100; } then { accept; } } term NON-MATCH { then { discard; } } when there is only one term containing a 'user-vlan-id' match condition, and no other terms in the firewall filter except discard, the discard action for non-matching traffic will only discard traffic with the same VLAN ID specified under 'user-vlan-id'. Other traffic (e.g. VLAN ID 200) will not be discarded. This unexpected behavior can lead to unintended traffic passing through the interface where the firewall filter is applied. This issue only affects systems using VXLANs. This issue affects Juniper Networks Junos OS on QFX5K Series: 18.1 versions prior to 18.1R3-S7, except 18.1R3; 18.2 versions prior to 18.2R2-S7, 18.2R3-S1; 18.3 versions prior to 18.3R1-S5, 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R1-S7, 18.4R2-S1, 18.4R3; 19.1 versions prior to 19.1R1-S5, 19.1R2; 19.2 versions prior to 19.2R1-S5, 19.2R2.
AnalysisAI
When configuring stateless firewall filters in Juniper Networks EX4600 and QFX 5000 Series devices using Virtual Extensible LAN protocol (VXLAN), the discard action will fail to discard traffic under. Rated medium severity (CVSS 5.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-203. When configuring stateless firewall filters in Juniper Networks EX4600 and QFX 5000 Series devices using Virtual Extensible LAN protocol (VXLAN), the discard action will fail to discard traffic under certain conditions. Given a firewall filter configuration similar to: family ethernet-switching { filter L2-VLAN { term ALLOW { from { user-vlan-id 100; } then { accept; } } term NON-MATCH { then { discard; } } when there is only one term containing a 'user-vlan-id' match condition, and no other terms in the firewall filter except discard, the discard action for non-matching traffic will only discard traffic with the same VLAN ID specified under 'user-vlan-id'. Other traffic (e.g. VLAN ID 200) will not be discarded. This unexpected behavior can lead to unintended traffic passing through the interface where the firewall filter is applied. This issue only affects systems using VXLANs.1 versions prior to 18.1R3-S7, except 18.1R3; 18.2 versions prior to 18.2R2-S7, 18.2R3-S1; 18.3 versions prior to 18.3R1-S5, 18.3R2-S4, 18.3R3; 18.4 versions prior to 18.4R1-S7, 18.4R2-S1, 18.4R3; 19.1 versions prior to 19.1R1-S5, 19.1R2; 19.2 versions prior to 19.2R1-S5, 19.2R2. Affected products include: Juniper Junos. Version information: prior to 18.1.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 does not properly handle DNAME records when parsing fe
named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 allows remote attackers to cause a denial of service (
A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series and SRX Series all
jsdm/ajax/port.php in J-Web in Juniper Junos before 10.4R13, 11.4 before 11.4R7, 12.1 before 12.1R5, 12.2 before 12.2R3,
Juniper Junos 11.4 before R11, 12.1 before R9, 12.1X44 before D30, 12.1X45 before D20, 12.1X46 before D15, 12.1X47 befor
NFX Series devices using Juniper Networks Junos OS are susceptible to a local command execution vulnerability thereby al
NFX Series devices using Juniper Networks Junos OS are susceptible to a local code execution vulnerability thereby allow
Insufficient validation of environment variables in the telnet client supplied in Junos OS can lead to stack-based buffe
An Out-of-Bounds Write vulnerability in the H.323 ALG of Juniper Networks Junos OS allows an unauthenticated, network-ba
On QFX10000 Series devices using Juniper Networks Junos OS when configured as transit IP/MPLS penultimate hop popping (P
A Missing Release of Memory after Effective Lifetime vulnerability in the kernel of Juniper Networks Junos OS allows an
An Uncontrolled Memory Allocation vulnerability leading to a Heap-based Buffer Overflow in the packet forwarding engine
Same weakness CWE-203 – Observable Discrepancy
View allSame technique Information Disclosure