Skip to main content

Am 100 Firmware CVE-2019-3938

HIGH
Insufficiently Protected Credentials (CWE-522)
2019-04-30 vulnreport@tenable.com
7.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 30, 2019 - 21:29 nvd
HIGH 7.8

DescriptionNVD

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.

AnalysisAI

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Insufficiently Protected Credentials (CWE-522), which allows attackers to obtain user credentials due to weak protection mechanisms. Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords. Affected products include: Crestron Am-100 Firmware, Crestron Am-101 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Hash passwords with strong algorithms (bcrypt, argon2), encrypt credentials in transit and at rest, never log credentials.

CVE-2019-3929 CRITICAL POC
9.8 Apr 30

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Ba

CVE-2019-3932 CRITICAL POC
9.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a

CVE-2019-3930 CRITICAL POC
9.8 Apr 30

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Ba

CVE-2019-3927 CRITICAL POC
9.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator

CVE-2019-3926 CRITICAL POC
9.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID

CVE-2019-3925 CRITICAL POC
9.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID

CVE-2019-3935 CRITICAL POC
9.1 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide sh

CVE-2019-3931 HIGH POC
8.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the cu

CVE-2019-3937 HIGH POC
7.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode,

CVE-2019-3939 CRITICAL
9.8 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator

CVE-2019-3934 MEDIUM POC
5.3 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sen

CVE-2019-3933 MEDIUM POC
5.3 Apr 30

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sim