Infinity Delta CVE-2019-25716

| EUVDEUVD-2019-20153 HIGH
External Control of System or Configuration Setting (CWE-15)
2026-06-01 VulnCheck GHSA-x6h5-p8qf-9j76
7.1
CVSS 4.0 · Vendor: VulnCheck
Share

Severity by source

Vendor (VulnCheck) PRIMARY
7.1 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (VulnCheck) · only source for this CVE.

CVSS VectorVendor: VulnCheck

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

3
Severity Changed
Jun 01, 2026 - 22:22 NVD
MEDIUM HIGH
CVSS changed
Jun 01, 2026 - 22:22 NVD
6.5 (MEDIUM) 7.1 (HIGH)
CVE Published
Jun 01, 2026 - 21:15 cve.org
HIGH 7.1

DescriptionCVE.org

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.

AnalysisAI

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network. Rated high severity (CVSS 7.1), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-15. Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity. Affected products include: Dräger Infinity Delta, Dräger Infinity Delta Xl, Dräger Infinity Kappa.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.