Skip to main content

Atmel Toolbox CVE-2019-15809

MEDIUM
Observable Discrepancy (CWE-203)
2019-10-03 cve@mitre.org
4.7
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
4.7 MEDIUM
AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack Vector
Local
Attack Complexity
High
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Oct 03, 2019 - 14:15 nvd
MEDIUM 4.7

DescriptionNVD

Smart cards from the Athena SCS manufacturer, based on the Atmel Toolbox 00.03.11.05 and the AT90SC chip, contain a timing side channel in ECDSA signature generation. This allows a local attacker, able to measure the duration of hundreds to thousands of signing operations, to compute the private key used. The issue occurs because the Atmel Toolbox 00.03.11.05 contains two versions of ECDSA signature functions, described as fast and secure, but the affected cards chose to use the fast version, which leaks the bit length of the random nonce via timing. This affects Athena IDProtect 010b.0352.0005, Athena IDProtect 010e.1245.0002, Athena IDProtect 0106.0130.0401, Athena IDProtect 010e.1245.0002, Valid S/A IDflex V 010b.0352.0005, SafeNet eToken 4300 010e.1245.0002, TecSec Armored Card 010e.0264.0001, and TecSec Armored Card 108.0264.0001.

AnalysisAI

Smart cards from the Athena SCS manufacturer, based on the Atmel Toolbox 00.03.11.05 and the AT90SC chip, contain a timing side channel in ECDSA signature generation. Rated medium severity (CVSS 4.7). Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-203. Smart cards from the Athena SCS manufacturer, based on the Atmel Toolbox 00.03.11.05 and the AT90SC chip, contain a timing side channel in ECDSA signature generation. This allows a local attacker, able to measure the duration of hundreds to thousands of signing operations, to compute the private key used. The issue occurs because the Atmel Toolbox 00.03.11.05 contains two versions of ECDSA signature functions, described as fast and secure, but the affected cards chose to use the fast version, which leaks the bit length of the random nonce via timing. This affects Athena IDProtect 010b.0352.0005, Athena IDProtect 010e.1245.0002, Athena IDProtect 0106.0130.0401, Athena IDProtect 010e.1245.0002, Valid S/A IDflex V 010b.0352.0005, SafeNet eToken 4300 010e.1245.0002, TecSec Armored Card 010e.0264.0001, and TecSec Armored Card 108.0264.0001. Affected products include: Microchip Atmel Toolbox, Athena-Scs Idprotect, Cryptsoft S\/A Idflex V, Tecsec Armored Card, Thalesgroup Etoken 4300.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.