Skip to main content

Re6300 Firmware CVE-2019-11535

CRITICAL
Command Injection (CWE-77)
2019-07-17 cve@mitre.org
9.8
CVSS 3.0 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A remote attacker could inject arbitrary commands into system command execution by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 5.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI. Affected products include: Linksys Re6400 Firmware, Linksys Re6300 Firmware. Version information: through 1.2.04.022.

Know when Re6300 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI.

Threat Intelligence Overview

EPSS Score
5.1%
Top 9% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 5.1%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

54
Low Medium High Critical
KEV: 0
EPSS: +5
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)NVD

cpe:2.3:o:linksys:re6400_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:linksys:re6300_firmware:*:*:*:*:*:*:*:*
CVE-2025-14134 HIGH POC
8.8 Dec 06

A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.0

CVE-2025-14136 HIGH POC
7.4 Dec 06

A stack-based buffer overflow in the Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 range extenders allows an

CVE-2025-14135 HIGH POC
7.4 Dec 06

Stack-based buffer overflow in the web management service of Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 r

CVE-2025-14133 HIGH POC
7.4 Dec 06

A stack-based buffer overflow in the Linksys RE-series WiFi range extenders (RE6250, RE6300, RE6350, RE6500, RE7000 and

CVE-2025-5447 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5438 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5445 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5444 MEDIUM POC
6.3 Jun 02

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.0

CVE-2025-5443 MEDIUM POC
6.3 Jun 02

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE900

CVE-2025-5446 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5442 MEDIUM POC
6.3 Jun 02

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and

CVE-2025-5441 MEDIUM POC
6.3 Jun 02

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.00

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy