Tia Administrator
CVE-2019-10915
HIGH
Severity by source
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
AnalysisAI
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. This Missing Authentication for Critical Function vulnerability could allow attackers to access critical functionality without authentication.
Technical ContextAI
This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Affected products include: Siemens Tia Administrator, Siemens Sinetplan.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Require authentication for all sensitive operations, implement defense in depth.
More in Tia Administrator
View allA vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-pr
A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application improperly va
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. Rated med