9Px Ups Firmware
CVE-2018-9280
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V6 - Authentication Credential protection in transit/storage
|
| Impact | CVSS score of 4.9 (MEDIUM). Attack characteristics: network attack vector, low complexity, high privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could obtain user credentials due to weak protection mechanisms by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
An issue was discovered on Eaton UPS 9PX 8000 SP devices. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Hash passwords with strong algorithms (bcrypt, argon2), encrypt credentials in transit and at rest, never log credentials.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Insufficiently Protected Credentials (CWE-522), which allows attackers to obtain user credentials due to weak protection mechanisms. An issue was discovered on Eaton UPS 9PX 8000 SP devices. The appliance discloses the SNMP version 3 user's password. The web page displayed by the appliance contains the password in cleartext. Passwords of the read and write users could be retrieved by browsing the source code of the webpage. Affected products include: Eaton 9Px Ups Firmware. Version information: version 3.
Know when 9Px Ups Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
An issue was discovered on Eaton UPS 9PX 8000 SP devices. The appliance discloses the SNMP version 3 user's password. The web page displayed by the appliance contains the password in cleartext. Passwords of the read and write users could be retrieved by browsing the source code of the webpage.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
More in 9Px Ups Firmware
View allAn issue was discovered on Eaton UPS 9PX 8000 SP devices. Rated high severity (CVSS 8.8), this vulnerability is remotely
An issue was discovered on Eaton UPS 9PX 8000 SP devices. Rated medium severity (CVSS 4.9), this vulnerability is remote
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB