Ts5600D1206 Firmware
CVE-2018-13319
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK
2 techniques across 2 tactics: Collection, Discovery The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | A remote attacker could access sensitive data that should not be disclosed by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Incorrect access control in get_portal_info in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to determine sensitive device information via an unauthenticated POST request. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. Incorrect access control in get_portal_info in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to determine sensitive device information via an unauthenticated POST request. Affected products include: Buffalo Ts5600D1206 Firmware. Version information: version 3.61.
Know when Ts5600D1206 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Incorrect access control in get_portal_info in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to determine sensitive device information via an unauthenticated POST request.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
More in Ts5600D1206 Firmware
View allIncorrect access control in nasapi in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to bypass authentication by
Incorrect access controls in nasapi in Buffalo TS5600D1206 version 3.61-0.10 allow attackers to call dangerous internal
System Command Injection in network.set_auth_settings in Buffalo TS5600D1206 version 3.70-0.10 allows attackers to execu
System command injection in User.create method in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to execute syst
Directory traversal in list_folders method in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to list directory c
Cross-site scripting in detail.html in Buffalo TS5600D1206 version 3.61-0.10 allows attackers to execute JavaScript via
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB