Sinumerik 828D V4 7 Firmware CVE-2018-11458

HIGH
Integer Overflow or Wraparound (CWE-190)
2018-12-12 productcert@siemens.com
8.1
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
8.1 HIGH
AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Dec 12, 2018 - 16:29 nvd
HIGH 8.1

DescriptionNVD

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.

AnalysisAI

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Integer Overflow (CWE-190), which allows attackers to cause unexpected behavior through arithmetic overflow. A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known. Affected products include: Siemens Sinumerik 828D V4.7 Firmware, Siemens Sinumerik 840D Sl V4.7 Firmware, Siemens Sinumerik 840D Sl V4.8 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate arithmetic operations, use safe integer libraries, check bounds before allocation.

Share

CVE-2018-11458 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy