Skip to main content
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK

2 techniques across 2 tactics: Collection, Discovery

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 5.3 (MEDIUM). Attack characteristics: adjacent network attack vector, high complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

An attacker could exploit this vulnerability to access sensitive data that should not be disclosed. No authentication is required to exploit this vulnerability.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.4% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon. Rated medium severity (CVSS 5.3), this vulnerability is no authentication required. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet. Affected products include: Philips Intellivue Mp2 Firmware, Philips Intellivue X2 Firmware, Philips Intellivue Mp30 Firmware, Philips Intellivue Mp50 Firmware, Philips Intellivue Mp70 Firmware.

Know when Intellivue Mp2 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 5.3 MEDIUM
AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

DescriptionNVD

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.

Threat Intelligence Overview

EPSS Score
0.4%
Top 66% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.4%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

26
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +26
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)NVD

cpe:2.3:o:philips:intellivue_mp2_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mp30_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mp50_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mp70_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_np90_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx450_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx500_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:avalon_fetal\/maternal_monitors_fm20_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:avalon_fetal\/maternal_monitors_fm30_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:avalon_fetal\/maternal_monitors_fm40_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:philips:avalon_fetal\/maternal_monitors_fm50_firmware:-:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy