Skip to main content

Vampset CVE-2017-7967

MEDIUM
Buffer Overflow (CWE-119)
2017-05-09 cybersecurity@se.com
5.5
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
5.5 MEDIUM
AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

1
CVE Published
May 09, 2017 - 17:29 cve.org
MEDIUM 5.5

DescriptionCVE.org

All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.

AnalysisAI

All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol. Affected products include: Schneider-Electric Vampset.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.