Northstar Controller
CVE-2017-2334
HIGH
Severity by source
AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionCVE.org
An information leak vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a network-based malicious attacker to perform a man-in-the-middle attack, thereby stealing authentic credentials from encrypted paths which are easily decrypted, and subsequently gain complete control of the system.
AnalysisAI
An information leak vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a network-based malicious attacker to perform a. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. An information leak vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a network-based malicious attacker to perform a man-in-the-middle attack, thereby stealing authentic credentials from encrypted paths which are easily decrypted, and subsequently gain complete control of the system. Affected products include: Juniper Northstar Controller. Version information: version 2.1.0.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.
More in Northstar Controller
View allA vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an
An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0
A vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an
A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pa
A vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a m
A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pa
A firewall bypass vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack
A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack
A persistent denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0
A vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an
An information disclosure vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Serv
A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack
Same weakness CWE-200 – Information Exposure
View allSame technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today