Multilink Ml3100 Firmware
CVE-2014-5419
CRITICAL
Severity by source
AV:N/AC:L/Au:N/C:C/I:C/A:C
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
AV:N/AC:L/Au:N/C:C/I:C/A:C
Lifecycle Timeline
1DescriptionCVE.org
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.
AnalysisAI
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-321. GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network. Affected products include: Ge Multilink Ml3100 Firmware, Ge Multilink Ml3100, Ge Multilink Ml3000 Firmware, Ge Multilink Ml3000, Ge Multilink Ml810 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Multilink Ml3100 Firmware
View allCross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multili
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and
Same weakness CWE-321 – Use of Hard-coded Cryptographic Key
View allSame technique Information Disclosure