Skip to main content

Wincc CVE-2012-3034

MEDIUM
Information Exposure (CWE-200)
2012-09-18 ics-cert@hq.dhs.gov
4.3
CVSS 2.0 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK

2 techniques across 2 tactics: Collection, Discovery

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 4.3 (MEDIUM). Attack characteristics: network attack vector, M complexity. EPSS exploitation probability: 0.52%.

Exploit ScenarioDerived

A remote attacker could access sensitive data that should not be disclosed by sending crafted requests to the affected application.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
Patch available 0.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable. This Exposure of Sensitive Information vulnerability could allow attackers to access sensitive data that should not be disclosed.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls. Affected products include: Siemens Simatic Pcs7, Siemens Wincc.

Know when Wincc gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 4.3 MEDIUM
AV:N/AC:M/Au:N/C:P/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
M
Confidentiality
P
Integrity
None
Availability
None

DescriptionCVE.org

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.

Threat Intelligence Overview

EPSS Score
0.5%
Top 33% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.5%
Patch available Yes
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

23
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +22
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)CVE.org

cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*

More in Wincc

View all
CVE-2017-12069 HIGH
8.2 Aug 30

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Ser

CVE-2023-30897 HIGH
7.8 Jun 13

A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Rated high severity (CVSS 7.8), this vu

CVE-2012-3032 HIGH
7.5 Sep 18

SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other prod

CVE-2013-3958 HIGH
7.5 Jun 14

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and

CVE-2013-3957 HIGH
7.5 Jun 14

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SI

CVE-2013-0674 MEDIUM
6.8 Mar 21

Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and

CVE-2015-2823 MEDIUM
6.8 Apr 08

Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before

CVE-2013-4911 MEDIUM
6.8 Aug 01

Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote atta

CVE-2014-4686 MEDIUM
6.8 Jul 24

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a ha

CVE-2012-3028 MEDIUM
6.8 Sep 18

Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC

CVE-2013-0675 MEDIUM
6.1 Mar 21

Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC

CVE-2014-4684 MEDIUM
6.0 Jul 24

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated