CVE-2025-40593 Jul 08, 11:15 MEDIUM This Month

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.

Denial Of Service Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
6.5
EPSS
0.1%
CVE-2024-32742 May 14, 16:17 HIGH This Week

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated high severity (CVSS 7.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
7.6
EPSS
0.4%
CVE-2024-32741 May 14, 16:17 CRITICAL Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
10.0
EPSS
0.6%
CVE-2024-32740 May 14, 16:17 CRITICAL Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
9.8
EPSS
0.7%
CVE-2023-49621 Jan 09, 10:15 CRITICAL PATCH Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Use of Default Credentials vulnerability could allow attackers to gain access using factory-default usernames and passwords.

Information Disclosure Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
9.8
EPSS
0.2%
CVE-2023-49252 Jan 09, 10:15 HIGH PATCH This Week

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.

Denial Of Service Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
7.5
EPSS
0.2%
CVE-2023-49251 Jan 09, 10:15 HIGH PATCH This Week

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity.

Authentication Bypass Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
8.8
EPSS
0.4%
CVE-2023-29131 Jul 11, 10:15 CRITICAL PATCH Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Incorrect Default Permissions vulnerability could allow attackers to access resources due to overly permissive default settings.

Privilege Escalation Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
10.0
EPSS
0.4%
CVE-2023-29130 Jul 11, 10:15 CRITICAL PATCH Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity.

Authentication Bypass Privilege Escalation Siemens Simatic Cn 4100 Firmware
NVD
CVSS 3.1
10.0
EPSS
0.6%
EPSS 0% CVSS 6.5
MEDIUM This Month

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.

Denial Of Service Siemens Simatic Cn 4100 Firmware
NVD
EPSS 0% CVSS 7.6
HIGH This Week

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated high severity (CVSS 7.6), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Siemens Simatic Cn 4100 Firmware
NVD
EPSS 1% CVSS 10.0
CRITICAL Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Siemens Simatic Cn 4100 Firmware
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Siemens Simatic Cn 4100 Firmware
NVD
EPSS 0% CVSS 9.8
CRITICAL PATCH Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Use of Default Credentials vulnerability could allow attackers to gain access using factory-default usernames and passwords.

Information Disclosure Siemens Simatic Cn 4100 Firmware
NVD
EPSS 0% CVSS 7.5
HIGH PATCH This Week

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.

Denial Of Service Siemens Simatic Cn 4100 Firmware
NVD
EPSS 0% CVSS 8.8
HIGH PATCH This Week

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity.

Authentication Bypass Siemens Simatic Cn 4100 Firmware
NVD
EPSS 0% CVSS 10.0
CRITICAL PATCH Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Incorrect Default Permissions vulnerability could allow attackers to access resources due to overly permissive default settings.

Privilege Escalation Siemens Simatic Cn 4100 Firmware
NVD
EPSS 1% CVSS 10.0
CRITICAL PATCH Act Now

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity.