Simatic Cn 4100 Firmware
CVE-2024-32740
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from Vendor (siemens) · only source for this CVE.
CVSS VectorVendor: siemens
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionCVE.org
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.
AnalysisAI
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Use of Hard-coded Credentials (CWE-798), which allows attackers to gain access using credentials embedded in source code. A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network. Affected products include: Siemens Simatic Cn 4100 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Remove hard-coded credentials, use environment variables or secrets management, rotate exposed credentials immediately.
More in Simatic Cn 4100 Firmware
View allA vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated critical severity (CVSS 10.0), this
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Rated critical severity (CVSS 10.0), this
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Rated critical severity (CVSS 10.0), this
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated critical severity (CVSS 9.8), this v
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated high severity (CVSS 8.8), this vulne
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). Rated high severity (CVSS 7.6), this vulne
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). Rated high severity (CVSS 7.5), this vulne
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control
Same weakness CWE-798 – Use of Hard-coded Credentials
View allSame technique Authentication Bypass