CVE-2019-6846 Oct 29, 19:15 MEDIUM This Month

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Bmxcra Firmware +1
NVD
CVSS 3.1
6.5
EPSS
1.0%
CVE-2019-6845 Oct 29, 19:15 HIGH This Week

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Tsxmcpc002M Firmware +20
NVD
CVSS 3.1
7.5
EPSS
1.1%
CVE-2019-6844 Oct 29, 19:15 MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Bmxcra Firmware +1
NVD
CVSS 3.1
4.9
EPSS
1.0%
CVE-2019-6843 Oct 29, 19:15 MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Bmxcra Firmware +1
NVD
CVSS 3.1
4.9
EPSS
1.0%
CVE-2019-6842 Oct 29, 19:15 MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Bmxcra Firmware +1
NVD
CVSS 3.1
4.9
EPSS
1.0%
CVE-2019-6841 Oct 29, 19:15 MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Bmxcra Firmware +1
NVD
CVSS 3.1
4.9
EPSS
24.4%
CVE-2019-6840 Sep 17, 20:15 CRITICAL Act Now

A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10,. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Meg6501 0001 Firmware Meg6501 0002 Firmware Meg6260 0410 Firmware +1
NVD
CVSS 3.1
9.8
EPSS
1.1%
CVE-2019-6839 Sep 17, 20:15 HIGH This Week

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 -. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

File Upload Schneider Electric Meg6501 0001 Firmware Meg6501 0002 Firmware Meg6260 0410 Firmware +1
NVD
CVSS 3.1
8.8
EPSS
1.1%
CVE-2019-6838 Sep 17, 20:15 MEDIUM This Month

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Meg6501 0001 Firmware Meg6501 0002 Firmware Meg6260 0410 Firmware +1
NVD
CVSS 3.1
6.5
EPSS
0.8%
CVE-2019-6837 Sep 17, 20:15 CRITICAL Act Now

A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

SSRF Schneider Electric Meg6501 0001 Firmware Meg6501 0002 Firmware Meg6260 0410 Firmware +1
NVD
CVSS 3.1
9.1
EPSS
1.0%
CVE-2019-6836 Sep 17, 20:15 HIGH This Week

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Meg6501 0001 Firmware Meg6501 0002 Firmware Meg6260 0410 Firmware +1
NVD
CVSS 3.1
7.5
EPSS
1.3%
CVE-2019-6835 Sep 17, 20:15 MEDIUM This Month

A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus,. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

XSS Schneider Electric Meg6501 0001 Firmware Meg6501 0002 Firmware Meg6260 0410 Firmware +1
NVD
CVSS 3.1
5.4
EPSS
0.5%
CVE-2019-6833 Sep 17, 20:15 MEDIUM This Month

A CWE-754 - Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT,. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Hmigto Firmware Hmisto Firmware Xbtgh Firmware +6
NVD
CVSS 3.1
6.5
EPSS
1.0%
CVE-2019-6832 Sep 17, 20:15 HIGH This Week

A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control. Rated high severity (CVSS 8.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Spacelynk Firmware Wiser For Knx Firmware
NVD
CVSS 3.1
8.3
EPSS
1.5%
CVE-2019-6831 Sep 17, 20:15 HIGH This Week

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active. Rated high severity (CVSS 8.6), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Bmxnor0200H Firmware
NVD
CVSS 3.1
8.6
EPSS
1.4%
CVE-2019-6830 Sep 17, 20:15 MEDIUM This Month

A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware
NVD
CVSS 3.1
5.9
EPSS
1.1%
CVE-2019-6829 Sep 17, 20:15 HIGH This Week

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware
NVD VulDB
CVSS 3.1
7.5
EPSS
0.4%
CVE-2019-6828 Sep 17, 20:15 HIGH This Week

A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD
CVSS 3.1
7.5
EPSS
1.5%
CVE-2019-6826 Sep 17, 20:15 HIGH This Week

A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Schneider Electric Somachine Hvac
NVD
CVSS 3.1
7.8
EPSS
1.2%
CVE-2019-6813 Sep 17, 20:15 HIGH This Week

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Bmxnor0200H Firmware Modicon M340 Firmware
NVD
CVSS 3.1
7.5
EPSS
2.1%
CVE-2019-6811 Sep 17, 20:15 HIGH This Week

An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon Quantum 140Noe77101 Firmware Modicon Quantum 140Noe77111 Firmware
NVD
CVSS 3.1
7.5
EPSS
1.3%
CVE-2019-6810 Sep 17, 20:15 HIGH This Week

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.

Authentication Bypass Schneider Electric Bmxnor0200H Firmware
NVD
CVSS 3.1
8.8
EPSS
1.7%
CVE-2019-6809 Sep 17, 20:15 HIGH This Week

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD
CVSS 3.1
7.5
EPSS
1.8%
CVE-2019-6827 Jul 15, 21:15 HIGH This Week

A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Memory Corruption Schneider Electric Interactive Graphical Scada System
NVD
CVSS 3.1
7.8
EPSS
1.3%
CVE-2019-6825 Jul 15, 21:15 HIGH This Week

A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Schneider Electric Proclima
NVD
CVSS 3.1
7.8
EPSS
1.2%
CVE-2019-6824 Jul 15, 21:15 CRITICAL Act Now

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Buffer Overflow Schneider Electric Proclima
NVD
CVSS 3.1
9.8
EPSS
4.5%
CVE-2019-6823 Jul 15, 21:15 CRITICAL Act Now

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Code Injection Schneider Electric Proclima
NVD
CVSS 3.1
9.8
EPSS
5.0%
CVE-2019-6822 Jul 15, 21:15 HIGH This Week

A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Denial Of Service Use After Free Memory Corruption Schneider Electric +1
NVD
CVSS 3.1
7.8
EPSS
3.7%
CVE-2019-10981 May 31, 21:29 HIGH PATCH This Week

In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. This Insufficiently Protected Credentials vulnerability could allow attackers to obtain user credentials due to weak protection mechanisms.

Information Disclosure Schneider Electric Citectscada Scada Expert Vijeo Citect
NVD
CVSS 3.1
7.8
EPSS
0.4%
CVE-2019-6808 May 22, 21:29 CRITICAL POC Act Now

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Authentication Bypass RCE Schneider Electric Modicon M580 Firmware Modicon M340 Firmware +2
NVD
CVSS 3.1
9.8
EPSS
8.2%
CVE-2019-6807 May 22, 21:29 HIGH POC This Week

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD
CVSS 3.1
7.5
EPSS
2.2%
CVE-2019-6806 May 22, 21:29 HIGH POC This Week

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD
CVSS 3.1
7.5
EPSS
2.3%
CVE-2019-6821 May 22, 20:29 MEDIUM PATCH This Month

30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.

Information Disclosure Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD
CVSS 3.1
6.5
EPSS
1.9%
CVE-2019-6820 May 22, 20:29 HIGH This Week

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a. Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M251 Firmware Modicon M241 Firmware Modicon M221 Firmware +9
NVD VulDB
CVSS 3.1
8.2
EPSS
0.3%
CVE-2019-6819 May 22, 20:29 HIGH This Week

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD VulDB
CVSS 3.1
7.5
EPSS
0.5%
CVE-2019-6816 May 22, 20:29 CRITICAL Act Now

In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Denial Of Service Code Injection Schneider Electric Modicon Quantum Firmware
NVD
CVSS 3.0
9.1
EPSS
1.5%
CVE-2019-6815 May 22, 20:29 CRITICAL Act Now

In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon Quantum Firmware
NVD
CVSS 3.0
9.1
EPSS
1.4%
CVE-2019-6812 May 22, 20:29 HIGH This Week

A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Bmx Nor 0200H Firmware
NVD
CVSS 3.1
7.2
EPSS
1.2%
CVE-2018-7852 May 22, 20:29 HIGH POC THREAT Act Now

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 12.9%.

Denial Of Service Schneider Electric Modicon M580 Firmware Modicon M340 Firmware Modicon Quantum Firmware +1
NVD VulDB
CVSS 3.1
7.5
EPSS
12.9%
CVE-2018-7821 May 22, 20:29 HIGH This Week

An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M221 Firmware Somachine Basic
NVD VulDB
CVSS 3.1
7.5
EPSS
0.5%
CVE-2019-10953 Apr 17, 15:29 HIGH This Week

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Siemens Abb Schneider Electric Modicon M221 Firmware +11
NVD VulDB GitHub
CVSS 3.1
7.5
EPSS
0.4%
CVE-2018-7837 Dec 24, 16:29 HIGH This Week

An Improper Restriction of XML External Entity Reference ('XXE') vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow the software to resolve documents. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XXE Schneider Electric Iiot Monior
NVD
CVSS 3.0
7.5
EPSS
1.2%
CVE-2018-7836 Dec 24, 16:29 CRITICAL Act Now

An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

File Upload Schneider Electric Iiot Monitor
NVD
CVSS 3.0
9.8
EPSS
32.0%
CVE-2018-7835 Dec 24, 16:29 HIGH This Week

An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in IIoT Monitor 3.1.38 which could allow access to files available to SYSTEM user. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Path Traversal Schneider Electric Iiot Monior
NVD
CVSS 3.0
7.5
EPSS
1.8%
CVE-2018-7832 Dec 24, 16:29 HIGH This Week

An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Pro Face Gp Pro Ex
NVD
CVSS 3.0
8.8
EPSS
2.2%
CVE-2018-7802 Dec 24, 16:29 HIGH PATCH This Week

A SQL Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could give access to the web interface with full privileges. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity.

SQLi Schneider Electric Evlink Parking Firmware
NVD
CVSS 3.0
8.8
EPSS
2.3%
CVE-2018-7801 Dec 24, 16:29 HIGH POC PATCH This Week

A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available.

RCE Code Injection Schneider Electric Evlink Parking Firmware
NVD
CVSS 3.1
8.8
EPSS
6.3%
CVE-2018-7800 Dec 24, 16:29 CRITICAL PATCH Act Now

A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Use of Hard-coded Credentials vulnerability could allow attackers to gain access using credentials embedded in source code.

Authentication Bypass Schneider Electric Evlink Parking Firmware
NVD
CVSS 3.0
9.8
EPSS
3.9%
CVE-2018-7796 Dec 24, 16:29 MEDIUM This Month

A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program. Rated medium severity (CVSS 6.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Schneider Electric Powersuite 2
NVD
CVSS 3.0
6.3
EPSS
0.7%
CVE-2018-7793 Dec 24, 16:29 HIGH This Week

A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.). Rated high severity (CVSS 8.7), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Foxboro Dcs Foxboro Evo Foxview +1
NVD
CVSS 3.0
8.7
EPSS
0.3%
CVE-2018-7833 Dec 17, 22:29 HIGH This Week

An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
7.5
EPSS
1.4%
CVE-2018-7812 Dec 17, 22:29 HIGH POC This Week

An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD GitHub
CVSS 3.0
7.5
EPSS
3.7%
CVE-2018-7804 Dec 17, 22:29 MEDIUM This Month

A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Open Redirect Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
6.1
EPSS
0.9%
CVE-2018-7797 Dec 17, 22:29 MEDIUM This Month

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Open Redirect Schneider Electric Ecostruxure Power Monitoring Expert Ecostruxure Energy Expert Ecostruxure Power Scada Operation
NVD
CVSS 3.0
6.1
EPSS
0.8%
CVE-2018-7831 Nov 30, 19:29 HIGH POC This Week

An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

XSS Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
8.8
EPSS
0.6%
CVE-2018-7830 Nov 30, 19:29 HIGH POC This Week

Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Denial Of Service Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
7.5
EPSS
2.4%
CVE-2018-7811 Nov 30, 19:29 CRITICAL POC Act Now

An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
9.8
EPSS
3.5%
CVE-2018-7810 Nov 30, 19:29 MEDIUM POC This Month

An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

XSS Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
6.1
EPSS
0.9%
CVE-2018-7809 Nov 30, 19:29 CRITICAL POC Act Now

An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware Modicom Premium Firmware Modicom Quantum Firmware +1
NVD
CVSS 3.0
9.8
EPSS
2.5%
CVE-2018-7807 Nov 30, 19:29 HIGH This Week

Data Center Expert, versions 7.5.0 and earlier, allows for the upload of a zip file from its user interface to the server. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Java Path Traversal Schneider Electric Struxureware Data Center Expert
NVD
CVSS 3.0
8.8
EPSS
1.3%
CVE-2018-7806 Nov 30, 19:29 HIGH This Week

Data Center Operation allows for the upload of a zip file from its user interface to the server. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Java Path Traversal Schneider Electric Struxureware Data Center Operation
NVD
CVSS 3.0
8.8
EPSS
1.3%
CVE-2018-7799 Nov 02, 17:29 HIGH This Week

A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Schneider Electric Software Update Utility
NVD
CVSS 3.0
7.8
EPSS
2.8%
CVE-2018-7798 Nov 02, 17:29 HIGH This Week

A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when. Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Somachine Basic
NVD VulDB
CVSS 3.1
8.2
EPSS
0.2%
CVE-2018-7792 Aug 29, 21:29 HIGH This Week

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
CVSS 3.1
7.5
EPSS
0.2%
CVE-2018-7791 Aug 29, 21:29 CRITICAL Act Now

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
CVSS 3.1
9.8
EPSS
0.4%
CVE-2018-7790 Aug 29, 21:29 CRITICAL Act Now

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
CVSS 3.1
9.8
EPSS
1.5%
CVE-2018-7795 Aug 29, 20:29 MEDIUM This Month

A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Java Schneider Electric Powerlogic Pm5560 Firmware
NVD VulDB
CVSS 3.1
5.4
EPSS
0.3%
CVE-2018-7789 Aug 29, 20:29 HIGH This Week

An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
CVSS 3.1
7.5
EPSS
0.7%
CVE-2018-3693 Jul 10, 21:29 MEDIUM PATCH This Month

Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a speculative buffer. Rated medium severity (CVSS 5.6).

Buffer Overflow Oracle Red Hat Intel Enterprise Linux +228
NVD
CVSS 3.1
5.6
EPSS
8.4%
CVE-2018-7787 Jul 03, 14:29 MEDIUM This Month

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric U Motion Builder
NVD
CVSS 3.0
5.3
EPSS
1.1%
CVE-2018-7786 Jul 03, 14:29 MEDIUM This Month

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Schneider Electric U Motion Builder
NVD
CVSS 3.0
6.1
EPSS
0.8%
CVE-2018-7785 Jul 03, 14:29 CRITICAL Act Now

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Command Injection Schneider Electric U Motion Builder
NVD
CVSS 3.0
9.8
EPSS
3.1%
CVE-2018-7784 Jul 03, 14:29 CRITICAL Act Now

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric U Motion
NVD
CVSS 3.0
9.8
EPSS
2.3%
CVE-2018-7783 Jul 03, 14:29 HIGH This Week

Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XXE Schneider Electric Somachine Basic
NVD
CVSS 3.0
7.5
EPSS
1.6%
CVE-2018-7782 Jul 03, 14:29 HIGH This Week

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Imps110 1Er Firmware Ibps110 1Er Firmware Imp1110 1 Firmware +17
NVD
CVSS 3.0
8.8
EPSS
0.8%
CVE-2018-7781 Jul 03, 14:29 HIGH This Week

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Privilege Escalation Schneider Electric Imps110 1Er Firmware Ibps110 1Er Firmware Imp1110 1 Firmware +17
NVD
CVSS 3.0
8.8
EPSS
0.6%
CVE-2018-7780 Jul 03, 14:29 CRITICAL Act Now

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set". Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Schneider Electric Imps110 1Er Firmware Ibps110 1Er Firmware Imp1110 1 Firmware +17
NVD
CVSS 3.0
9.8
EPSS
1.2%
CVE-2018-7779 Jul 03, 14:29 HIGH This Week

In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Homelynk Firmware Spacelynk Firmware Wiser For Knx Firmware
NVD
CVSS 3.0
7.5
EPSS
1.4%
CVE-2018-7778 Jul 03, 14:29 CRITICAL Act Now

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Evlink Charging Station Firmware
NVD
CVSS 3.0
9.8
EPSS
2.1%
CVE-2018-7777 Jul 03, 14:29 HIGH POC THREAT This Week

The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

PHP Information Disclosure Schneider Electric U Motion Builder
NVD Exploit-DB
CVSS 3.0
8.8
EPSS
31.8%
CVE-2018-7776 Jul 03, 14:29 MEDIUM This Month

The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP Information Disclosure Schneider Electric U Motion Builder
NVD
CVSS 3.0
4.3
EPSS
0.7%
CVE-2018-7774 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
CVE-2018-7773 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
CVE-2018-7772 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
CVE-2018-7771 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

PHP Path Traversal Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.0
EPSS
1.4%
CVE-2018-7770 Jul 03, 14:29 MEDIUM This Month

The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP Path Traversal Schneider Electric U Motion
NVD
CVSS 3.0
6.5
EPSS
1.3%
CVE-2018-7769 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
CVE-2018-7768 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
CVE-2018-7767 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
CVE-2018-7766 Jul 03, 14:29 HIGH This Week

The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric U Motion Builder
NVD
CVSS 3.0
8.8
EPSS
1.0%
EPSS 1% CVSS 6.5
MEDIUM This Month

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 1% CVSS 7.5
HIGH This Week

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Modicon M580 Firmware +22
NVD
EPSS 1% CVSS 4.9
MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 1% CVSS 4.9
MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 1% CVSS 4.9
MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 24% CVSS 4.9
MEDIUM This Month

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA. Rated medium severity (CVSS 4.9), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10,. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Meg6501 0001 Firmware +3
NVD
EPSS 1% CVSS 8.8
HIGH This Week

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 -. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

File Upload Schneider Electric Meg6501 0001 Firmware +3
NVD
EPSS 1% CVSS 6.5
MEDIUM This Month

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Meg6501 0001 Firmware +3
NVD
EPSS 1% CVSS 9.1
CRITICAL Act Now

A Server-Side Request Forgery (SSRF): CWE-918 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

SSRF Schneider Electric Meg6501 0001 Firmware +3
NVD
EPSS 1% CVSS 7.5
HIGH This Week

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Meg6501 0001 Firmware +3
NVD
EPSS 1% CVSS 5.4
MEDIUM This Month

A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus,. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

XSS Schneider Electric Meg6501 0001 Firmware +3
NVD
EPSS 1% CVSS 6.5
MEDIUM This Month

A CWE-754 - Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT,. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Hmigto Firmware +8
NVD
EPSS 1% CVSS 8.3
HIGH This Week

A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control. Rated high severity (CVSS 8.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Spacelynk Firmware +1
NVD
EPSS 1% CVSS 8.6
HIGH This Week

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active. Rated high severity (CVSS 8.6), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Bmxnor0200H Firmware
NVD
EPSS 1% CVSS 5.9
MEDIUM This Month

A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the. Rated medium severity (CVSS 5.9), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware
NVD
EPSS 0% CVSS 7.5
HIGH This Week

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +1
NVD VulDB
EPSS 2% CVSS 7.5
HIGH This Week

A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 1% CVSS 7.8
HIGH This Week

A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Schneider Electric Somachine Hvac
NVD
EPSS 2% CVSS 7.5
HIGH This Week

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Bmxnor0200H Firmware +1
NVD
EPSS 1% CVSS 7.5
HIGH This Week

An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon Quantum 140Noe77101 Firmware +1
NVD
EPSS 2% CVSS 8.8
HIGH This Week

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.

Authentication Bypass Schneider Electric Bmxnor0200H Firmware
NVD
EPSS 2% CVSS 7.5
HIGH This Week

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 1% CVSS 7.8
HIGH This Week

A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Memory Corruption Schneider Electric +1
NVD
EPSS 1% CVSS 7.8
HIGH This Week

A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Schneider Electric Proclima
NVD
EPSS 4% CVSS 9.8
CRITICAL Act Now

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Buffer Overflow Schneider Electric +1
NVD
EPSS 5% CVSS 9.8
CRITICAL Act Now

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Code Injection Schneider Electric +1
NVD
EPSS 4% CVSS 7.8
HIGH This Week

A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Denial Of Service Use After Free +3
NVD
EPSS 0% CVSS 7.8
HIGH PATCH This Week

In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. This Insufficiently Protected Credentials vulnerability could allow attackers to obtain user credentials due to weak protection mechanisms.

Information Disclosure Schneider Electric Citectscada +1
NVD
EPSS 8% CVSS 9.8
CRITICAL POC Act Now

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Authentication Bypass RCE Schneider Electric +4
NVD
EPSS 2% CVSS 7.5
HIGH POC This Week

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 2% CVSS 7.5
HIGH POC This Week

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 2% CVSS 6.5
MEDIUM PATCH This Month

30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity.

Information Disclosure Schneider Electric Modicon M580 Firmware +3
NVD
EPSS 0% CVSS 8.2
HIGH This Week

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a. Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M251 Firmware +11
NVD VulDB
EPSS 0% CVSS 7.5
HIGH This Week

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD VulDB
EPSS 1% CVSS 9.1
CRITICAL Act Now

In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Denial Of Service Code Injection +2
NVD
EPSS 1% CVSS 9.1
CRITICAL Act Now

In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon Quantum Firmware
NVD
EPSS 1% CVSS 7.2
HIGH This Week

A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Bmx Nor 0200H Firmware
NVD
EPSS 13% CVSS 7.5
HIGH POC THREAT Act Now

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 12.9%.

Denial Of Service Schneider Electric Modicon M580 Firmware +3
NVD VulDB
EPSS 1% CVSS 7.5
HIGH This Week

An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Schneider Electric Modicon M221 Firmware +1
NVD VulDB
EPSS 0% CVSS 7.5
HIGH This Week

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Siemens Abb +13
NVD VulDB GitHub
EPSS 1% CVSS 7.5
HIGH This Week

An Improper Restriction of XML External Entity Reference ('XXE') vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow the software to resolve documents. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XXE Schneider Electric Iiot Monior
NVD
EPSS 32% CVSS 9.8
CRITICAL Act Now

An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

File Upload Schneider Electric Iiot Monitor
NVD
EPSS 2% CVSS 7.5
HIGH This Week

An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in IIoT Monitor 3.1.38 which could allow access to files available to SYSTEM user. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Path Traversal Schneider Electric Iiot Monior
NVD
EPSS 2% CVSS 8.8
HIGH This Week

An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Pro Face Gp Pro Ex
NVD
EPSS 2% CVSS 8.8
HIGH PATCH This Week

A SQL Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could give access to the web interface with full privileges. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity.

SQLi Schneider Electric Evlink Parking Firmware
NVD
EPSS 6% CVSS 8.8
HIGH POC PATCH This Week

A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available.

RCE Code Injection Schneider Electric +1
NVD
EPSS 4% CVSS 9.8
CRITICAL PATCH Act Now

A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Use of Hard-coded Credentials vulnerability could allow attackers to gain access using credentials embedded in source code.

Authentication Bypass Schneider Electric Evlink Parking Firmware
NVD
EPSS 1% CVSS 6.3
MEDIUM This Month

A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program. Rated medium severity (CVSS 6.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Schneider Electric Powersuite 2
NVD
EPSS 0% CVSS 8.7
HIGH This Week

A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.). Rated high severity (CVSS 8.7), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Foxboro Dcs +3
NVD
EPSS 1% CVSS 7.5
HIGH This Week

An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 4% CVSS 7.5
HIGH POC This Week

An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware +3
NVD GitHub
EPSS 1% CVSS 6.1
MEDIUM This Month

A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Open Redirect Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 1% CVSS 6.1
MEDIUM This Month

A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Open Redirect Schneider Electric Ecostruxure Power Monitoring Expert +2
NVD
EPSS 1% CVSS 8.8
HIGH POC This Week

An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

XSS Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 2% CVSS 7.5
HIGH POC This Week

Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Denial Of Service Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 3% CVSS 9.8
CRITICAL POC Act Now

An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 1% CVSS 6.1
MEDIUM POC This Month

An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

XSS Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 2% CVSS 9.8
CRITICAL POC Act Now

An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Information Disclosure Schneider Electric Modicom M340 Firmware +3
NVD
EPSS 1% CVSS 8.8
HIGH This Week

Data Center Expert, versions 7.5.0 and earlier, allows for the upload of a zip file from its user interface to the server. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Java Path Traversal Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

Data Center Operation allows for the upload of a zip file from its user interface to the server. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Java Path Traversal Schneider Electric +1
NVD
EPSS 3% CVSS 7.8
HIGH This Week

A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RCE Schneider Electric Software Update Utility
NVD
EPSS 0% CVSS 8.2
HIGH This Week

A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when. Rated high severity (CVSS 8.2), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Somachine Basic
NVD VulDB
EPSS 0% CVSS 7.5
HIGH This Week

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
EPSS 0% CVSS 9.8
CRITICAL Act Now

A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
EPSS 2% CVSS 9.8
CRITICAL Act Now

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
EPSS 0% CVSS 5.4
MEDIUM This Month

A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Java Schneider Electric +1
NVD VulDB
EPSS 1% CVSS 7.5
HIGH This Week

An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Modicon M221 Firmware
NVD VulDB
EPSS 8% CVSS 5.6
MEDIUM PATCH This Month

Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a speculative buffer. Rated medium severity (CVSS 5.6).

Buffer Overflow Oracle Red Hat +230
NVD
EPSS 1% CVSS 5.3
MEDIUM This Month

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric U Motion Builder
NVD
EPSS 1% CVSS 6.1
MEDIUM This Month

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Schneider Electric U Motion Builder
NVD
EPSS 3% CVSS 9.8
CRITICAL Act Now

In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Command Injection Schneider Electric +1
NVD
EPSS 2% CVSS 9.8
CRITICAL Act Now

In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric U Motion
NVD
EPSS 2% CVSS 7.5
HIGH This Week

Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XXE Schneider Electric Somachine Basic
NVD
EPSS 1% CVSS 8.8
HIGH This Week

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Schneider Electric Imps110 1Er Firmware +19
NVD
EPSS 1% CVSS 8.8
HIGH This Week

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Privilege Escalation Schneider Electric Imps110 1Er Firmware +19
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set". Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Schneider Electric Imps110 1Er Firmware +19
NVD
EPSS 1% CVSS 7.5
HIGH This Week

In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Homelynk Firmware +2
NVD
EPSS 2% CVSS 9.8
CRITICAL Act Now

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Schneider Electric Evlink Charging Station Firmware
NVD
EPSS 32% CVSS 8.8
HIGH POC THREAT This Week

The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

PHP Information Disclosure Schneider Electric +1
NVD Exploit-DB
EPSS 1% CVSS 4.3
MEDIUM This Month

The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP Information Disclosure Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

SQLi Schneider Electric U Motion Builder
NVD
EPSS 1% CVSS 8.0
HIGH This Week

The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

PHP Path Traversal Schneider Electric +1
NVD
EPSS 1% CVSS 6.5
MEDIUM This Month

The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP Path Traversal Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric +1
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

PHP SQLi Schneider Electric +1
NVD