Skip to main content

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jul 03, 2018 - 14:29 nvd
HIGH 8.8

DescriptionNVD

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.

AnalysisAI

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-311. In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation. Affected products include: Schneider-Electric Imps110-1 Firmware, Schneider-Electric Imps110-1E Firmware, Schneider-Electric Imps110-1Er Firmware, Schneider-Electric Ibps110-1Er Firmware, Schneider-Electric Imp1110-1 Firmware. Version information: prior to 3.29.69.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2018-7780 CRITICAL
9.8 Jul 03

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer

CVE-2018-7238 CRITICAL
9.8 Mar 09

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmw

CVE-2018-7233 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7232 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7231 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7229 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7228 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7237 CRITICAL
9.1 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7782 HIGH
8.8 Jul 03

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authentic

CVE-2018-7230 HIGH
8.8 Mar 09

A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Elect

CVE-2018-7236 HIGH
8.1 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7235 HIGH
7.5 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

Share

CVE-2018-7781 vulnerability details – vuln.today