Skip to main content

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Mar 09, 2018 - 23:29 nvd
CRITICAL 9.8

DescriptionNVD

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

AnalysisAI

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Use of Hard-coded Credentials vulnerability could allow attackers to gain access using credentials embedded in source code.

Technical ContextAI

This vulnerability is classified as Use of Hard-coded Credentials (CWE-798), which allows attackers to gain access using credentials embedded in source code. A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials. Affected products include: Schneider-Electric Mps110-1 Firmware, Schneider-Electric Imps110-1Er Firmware, Schneider-Electric Ibps110-1Er Firmware, Schneider-Electric Imp1110-1 Firmware, Schneider-Electric Imp1110-1E Firmware. Version information: prior to 3.29.67.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Remove hard-coded credentials, use environment variables or secrets management, rotate exposed credentials immediately.

CVE-2018-7238 CRITICAL
9.8 Mar 09

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmw

CVE-2018-7233 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7232 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7231 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7228 CRITICAL
9.8 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7237 CRITICAL
9.1 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7230 HIGH
8.8 Mar 09

A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Elect

CVE-2018-7236 HIGH
8.1 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7235 HIGH
7.5 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7234 HIGH
7.5 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which

CVE-2018-7227 MEDIUM
5.3 Mar 09

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which