Modicom M340 Firmware
CVE-2018-7810
MEDIUM
Severity by source
AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Lifecycle Timeline
1DescriptionNVD
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on.
AnalysisAI
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on. Affected products include: Schneider-Electric Modicom M340 Firmware, Schneider-Electric Modicom Premium Firmware, Schneider-Electric Modicom Quantum Firmware, Schneider-Electric Modicom Bmxnor0200H Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
More in Modicom M340 Firmware
View allAn Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLC
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLC
An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded we
An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premiu
Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedd
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quant
Same weakness CWE-79 – Cross-site Scripting (XSS)
View allShare
External POC / Exploit Code
Leaving vuln.today