Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach device webserver on network
-
DeliverySend crafted password-change request
-
ExploitBypass authentication (CWE-294)
-
ExecutionLog in as admin
-
ImpactModify device configuration or I/O
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Replay attack prevention
|
| Exploitation Conditions | The target 1732E ArmorBlock I/O module's embedded webserver must be enabled and network-reachable by the attacker; exploitation then requires no credentials because the flaw (CWE-294) lets the password be changed without authentication (PR:N, no UI). The primary limiting factor is network exposure: these modules are intended for segmented industrial control networks, so proper OT network segmentation that isolates the device web interface from untrusted networks substantially constrains who can reach and exploit it. No specific non-default product feature or configuration toggle is named in the description as a prerequisite. |
| Impact | Signals align toward genuine priority within affected environments but with important caveats. The vendor-supplied CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N) describes a network-reachable, low-complexity, unauthenticated attack with no user interaction, and CWE-294 (Authentication Bypass by Capture-replay / spoofing) is consistent with the description's claim that the webserver password can be changed without valid credentials. Impact is scoped to integrity and availability (VC:N/VI:H/VA:H): an attacker does not read data but can seize the admin account and alter device configuration, matching the 8.8 severity. Critically, there is NO EPSS score, NO CISA KEV listing, and NO public POC in the provided data, so the high CVSS reflects theoretical exploitability rather than observed exploitation - this is no public exploit identified at time of analysis, not confirmed active exploitation. The 'network' vector must be read in OT context: these are industrial distributed I/O modules normally deployed on segmented control networks, so real-world reach depends heavily on whether the device's web interface is exposed. Treat as a high-priority patch for exposed/flat OT networks and a lower-urgency item where the module is properly isolated. |
| Exploit ScenarioDerived | An attacker with network reachability to a 1732E ArmorBlock I/O module's embedded webserver sends a crafted request that resets or sets the webserver password without providing any existing credentials, exploiting the authentication bypass. The attacker then logs in with the new password, takes over the admin account, and alters device I/O or configuration, potentially disrupting the industrial process. No public exploit code is identified in the available data, so this scenario is inferred from the CVSS vector (AV:N/AC:L/PR:N/UI:N) and description. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 13, 2026
Unauthenticated modification of the embedded webserver password on Rockwell Automation 1732E ArmorBlock I/O modules allows any network-reachable attacker to seize the administrative account and alter device configuration. The flaw is rated 8.8 (CVSS 4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VI:H/VA:H, no confidentiality impact), matching an authentication-bypass class (CWE-294) and confirmed by the independent assessment as CVSS:3.1 AV:N/AC:L/PR:N/UI:N with C:N/I:H/A:H. No public exploit code and no confirmed active exploitation (CISA KEV) were identified at time of analysis, and real-world exposure depends on whether the module's webserver is reachable from untrusted networks rather than being contained by OT segmentation.
RemediationAI
No vendor-released patch with an exact version was identified in the provided data, so the first step is to check Rockwell Automation advisory SD1801 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html) for the current firmware remediation or interim guidance and apply it to each affected 1732E ArmorBlock I/O module. Until firmware is available, the highest-leverage compensating control is network containment: keep these modules on segmented OT networks with no path from enterprise IT, guest, or internet-facing networks to the module webserver, using VLANs, industrial firewalls, or ACLs that allow only the specific engineering workstations that require access - the trade-off is that configuration and diagnostics must originate from approved hosts. Where the webserver is not needed for the device's operational role, disabling or otherwise restricting it removes the attack surface entirely, at the cost of losing remote web-based configuration; where it must remain enabled, restrict reachability to a management VLAN and monitor for unexpected password-change requests or authentication events on the module. Because exploitation requires no credentials (PR:N) and no user interaction (UI:N), host-based or credential-based defenses provide little protection, so exposure reduction via segmentation should be treated as the primary near-term mitigation.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The 1732E ArmorBlock I/O is a Rockwell Automation on-machine distributed I/O block for industrial control systems that ships with an embedded configuration webserver; the CPE entry cpe:2.3:a:rockwell_automation:1732e_armorblock®_i/o:*:*:*:*:*:*:*:* uses a wildcard version, indicating the issue is tracked against the product line rather than a single firmware build. The root cause class is CWE-294 (authentication bypass, typically realized as acceptance of a replayed or unauthenticated request), meaning the webserver's password-change function does not verify a valid current credential or authenticated session before committing the new password. Both the vendor vector (CVSS 4.0 PR:N/UI:N with VI:H/VA:H and VC:N) and the independent CVSS 3.1 assessment (PR:N/UI:N, C:N/I:H/A:H) agree that no privileges and no user interaction are required, that data confidentiality is not impacted, and that the exposure is one of unauthorized state change: an attacker rewrites the admin credential and then modifies configuration, with availability impact arising from potential disruption of the I/O device's function. The attack surface is the module's network-facing web interface, so exploitability is a function of network reachability rather than of any credential or client-side precondition.
Know when 1732E Armorblock I O gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
Unauthenticated network password change (PR:N, AV:N, AC:L); no data disclosure so C:N, but admin takeover corrupts config (I:H) and can lock out operators (A:H).
Primary rating from Vendor (Rockwell).
CVSS VectorVendor: Rockwell
DescriptionCVE.org
A security issue exists within 1732E ArmorBlock® I/O, where an unauthenticated attacker can change the device's webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration.
Executive ViewAI
Rockwell Automation 1732E ArmorBlock I/O modules - control hardware deployed on plant-floor networks - can have their embedded webserver administrative password changed by an unauthenticated, network-reachable party, allowing device configuration to be seized and altered. With no vendor-released patch identified and exposure determined largely by whether the webserver is reachable from untrusted networks, the risk is concentrated in organizations with weak OT segmentation or incomplete inventories of these modules. Leadership should treat this as a production-integrity and availability concern for manufacturing and industrial operations rather than an enterprise IT issue.
No vendor-released patch identified at time of analysis. Interim mitigations: restrict or block network access to the 1732E embedded webserver (TCP 80/443) from untrusted networks; disable the webserver where not operationally required; enforce OT segmentation, VLANs, and firewall/ACL rules so modules are reachable only from trusted control hosts; monitor ICS traffic and configuration baselines for unauthorized administrative changes; maintain known-good device configuration backups for rapid restoration; and obtain interim guidance from Rockwell Automation support. Password rotation alone is not effective because the attacker can modify the administrative password unauthenticated.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.