Skip to main content

CVE-2021-27289

CRITICAL
Authentication Bypass by Capture-replay (CWE-294)
2025-04-15 cve@mitre.org
9.1
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.1 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
High

Lifecycle Timeline

3
Analysis Generated
Mar 28, 2026 - 18:36 vuln.today
PoC Detected
Apr 16, 2025 - 15:15 vuln.today
Public exploit code
CVE Published
Apr 15, 2025 - 18:15 nvd
CRITICAL 9.1

DescriptionCVE.org

A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix (Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12), where the Zigbee anti-replay mechanism - based on the frame counter field - is improperly implemented. As a result, an attacker within wireless range can resend captured packets with a higher sequence number, which the devices incorrectly accept as legitimate messages. This allows spoofed commands to be injected without authentication, triggering false alerts and misleading the user through notifications in the mobile application used to monitor the network.

AnalysisAI

A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix (Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12), where the Zigbee. Rated critical severity (CVSS 9.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-294. A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix (Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12), where the Zigbee anti-replay mechanism - based on the frame counter field - is improperly implemented. As a result, an attacker within wireless range can resend captured packets with a higher sequence number, which the devices incorrectly accept as legitimate messages. This allows spoofed commands to be injected without authentication, triggering false alerts and misleading the user through notifications in the mobile application used to monitor the network.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2021-27289 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy