Skip to main content

Autodesk Installer EUVDEUVD-2026-57238

| CVE-2026-14478 HIGH
Incorrect Permission Assignment for Critical Resource (CWE-732)
2026-08-12 autodesk GHSA-m4rg-6628-ff5c
7.8
CVSS 3.1 · Vendor: autodesk
Share

Severity by source

Vendor (autodesk) PRIMARY
7.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
vuln.today AI
7.8 HIGH

Local vector with low-privileged execution required; no user interaction beyond running the binary; full CIA impact via named pipe injection; scope unchanged as compromise remains within the local system.

3.1 AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (autodesk).

CVSS VectorVendor: autodesk

Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Analysis Generated
Aug 12, 2026 - 15:39 vuln.today
CVE Published
Aug 12, 2026 - 14:54 nvd
HIGH 7.8

DescriptionCVE.org

A maliciously created executable, when executed on the victim's machine, may allow a local low-privileged attacker to inject unauthenticated IPC messages into named pipes, modify pipe permissions or ownership, and potentially impact confidentiality, integrity, and availability.

AnalysisAI

Local privilege escalation in Autodesk's ODIS (Online Deployment & Installation Service) installer allows a low-privileged local attacker to inject unauthenticated IPC messages into named pipes by executing a specially crafted binary on the target machine. The root cause is incorrect permission assignment (CWE-732) on named pipe resources, permitting unauthorized low-privileged processes to connect, write, or manipulate pipe ownership in ways that fully compromise confidentiality, integrity, and availability. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires the attacker to hold a valid low-privileged local account on the target Windows system, as confirmed by the AV:L and PR:L metrics in the CVSS vector. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 7.8 HIGH score (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) accurately reflects a local privilege escalation with full CIA triad impact, low attack complexity, and no user interaction required beyond running the malicious binary. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Update the Autodesk ODIS installer to the latest available version by downloading and running the patched installer directly from the vendor-provided URL: https://emsfs.autodesk.com/utility/odis/1/installer/latest/AdODIS-installer.exe. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, identify all systems running Autodesk ODIS and prioritize by business criticality and data sensitivity. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

EUVD-2026-57238 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy