Severity by source
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Local vector with low-privileged execution required; no user interaction beyond running the binary; full CIA impact via named pipe injection; scope unchanged as compromise remains within the local system.
Primary rating from Vendor (autodesk).
CVSS VectorVendor: autodesk
Lifecycle Timeline
2DescriptionCVE.org
A maliciously created executable, when executed on the victim's machine, may allow a local low-privileged attacker to inject unauthenticated IPC messages into named pipes, modify pipe permissions or ownership, and potentially impact confidentiality, integrity, and availability.
AnalysisAI
Local privilege escalation in Autodesk's ODIS (Online Deployment & Installation Service) installer allows a low-privileged local attacker to inject unauthenticated IPC messages into named pipes by executing a specially crafted binary on the target machine. The root cause is incorrect permission assignment (CWE-732) on named pipe resources, permitting unauthorized low-privileged processes to connect, write, or manipulate pipe ownership in ways that fully compromise confidentiality, integrity, and availability. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | Exploitation requires the attacker to hold a valid low-privileged local account on the target Windows system, as confirmed by the AV:L and PR:L metrics in the CVSS vector. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 7.8 HIGH score (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) accurately reflects a local privilege escalation with full CIA triad impact, low attack complexity, and no user interaction required beyond running the malicious binary. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | Full exploit scenario with step-by-step reproduction available after sign-in. |
| Remediation | Update the Autodesk ODIS installer to the latest available version by downloading and running the patched installer directly from the vendor-provided URL: https://emsfs.autodesk.com/utility/odis/1/installer/latest/AdODIS-installer.exe. … Detailed patch versions, workarounds, and compensating controls in full report. |
Recommended ActionAI
Within 24 hours, identify all systems running Autodesk ODIS and prioritize by business criticality and data sensitivity. …
Sign in for detailed remediation steps and compensating controls.
Threat intelligence, references, and detailed analysis are available after sign-in.
Improper Restriction of Excessive Authentication Attempts in GitHub repository modoboa/modoboa-installer prior to 2.0.4.
Privilege escalation vulnerability in Autodesk Installer applications where a maliciously crafted binary file exploits a
A maliciously crafted DLL file when placed in temporary files and folders that are leveraged by the Autodesk Installer c
A maliciously crafted DLL file can be forced to write beyond allocated boundaries in the Autodesk installer when parsing
The Autodesk Installer IPC frame parser fails to properly validate attacker-controlled position and offset fields (CWE-1
A maliciously crafted file, when executed on the victim's machine, can lead to privilege escalation to NT AUTHORITY/SYST
Same technique Code Injection
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-57238