Skip to main content

Evbee DC-80 EUVDEUVD-2026-43330

| CVE-2026-22099 HIGH
Improper Authentication (CWE-287)
2026-07-13 DIVD
8.7
CVSS 4.0 · Vendor: DIVD
Share

Severity by source

Vendor (DIVD) PRIMARY
8.7 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
8.8 HIGH

Bluetooth range gives AV:A with low complexity, and the unauthenticated command interface (PR:N, no UI) yields full C/I/A impact via info leak, firmware push, and reboot.

3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (DIVD).

CVSS VectorVendor: DIVD

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

3
Patch available
Jul 13, 2026 - 12:01 EUVD
Analysis Generated
Jul 13, 2026 - 11:10 vuln.today
CVE Published
Jul 13, 2026 - 09:10 cve.org
HIGH 8.7

DescriptionCVE.org

The charging station does not require authentication for Bluetooth commands to perform actions. The functionality exposed includes sensitive information leakage, triggering reboots, or pushing a firmware update URL.

AnalysisAI

Bluetooth authentication bypass in the Evbee DC-80 DC EV charging station lets an attacker within radio range issue privileged commands without any credentials, enabling sensitive information disclosure, forced reboots, and - most dangerously - the ability to push an arbitrary firmware update URL to the device. Reported by DIVD (DIVD-2026-00001), it carries CVSS 4.0 base 8.7 (High). No public exploit identified at time of analysis, and it is not listed in CISA KEV.

Technical ContextAI

The affected device is an Evbee DC-80 electric-vehicle DC charging station (cpe:2.3:a:evbee:dc-80). Like many EV chargers and IoT appliances, it exposes a local Bluetooth (BLE) control channel used for provisioning, diagnostics, and configuration. The root cause maps to CWE-287 (Improper Authentication): the Bluetooth command interface accepts action commands without verifying the identity of the caller, so any device that can pair or connect over the air can invoke functions intended only for an authorized operator. The most severe exposed function - supplying a firmware update URL - effectively lets an unauthenticated peer point the charger at an attacker-controlled firmware source, which is a direct integrity-compromise primitive on embedded hardware.

RemediationAI

No vendor-released patch identified at time of analysis; the only reference is the DIVD coordination advisory at https://csirt.divd.nl/DIVD-2026-00001/, which should be monitored for a fixed firmware version. As compensating controls until a fix is available: physically restrict proximity access to the charger where feasible and site chargers away from areas where an attacker could linger within Bluetooth range; disable or unpair the Bluetooth management interface if the unit supports operating without it (trade-off: loss of local BLE-based provisioning and diagnostics); avoid leaving the device in a pairable/discoverable state after commissioning; and treat any unexpected reboot or firmware-version change as a potential compromise indicator. Because the firmware-update-URL function is the highest-risk capability, confirm with Evbee whether firmware update sources can be pinned or signature-verified, and apply the official firmware update through a trusted channel once released.

Share

EUVD-2026-43330 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy