Skip to main content

WatchGuard Fireware OS EUVDEUVD-2026-111146

| CVE-2026-90465 CRITICAL
Authentication Bypass by Spoofing (CWE-290)
2026-10-27 WatchGuard GHSA-rwrf-f344-f6wx
9.4
CVSS 4.0 · Vendor: WatchGuard
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain position on cluster interconnect
  2. Delivery
    Craft FireCluster Sync request
  3. Exploit
    Bypass missing authentication check
  4. Execution
    Invoke privileged management action as root
  5. Impact
    Full firewall compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Anti-spoofing controls
MITRE ATT&CK

1 technique across 1 tactic: Defense Evasion

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires that the target run WatchGuard FireCluster (the high-availability clustering feature) and that the attacker be positioned on the cluster interconnect - either as a compromised cluster peer or an on-path/man-in-the-middle attacker on the sync network (consistent with AV:A, adjacent). The FireCluster Sync processing performs no authentication (CWE-290), so once that position is held, a single crafted request invokes root-level management actions without credentials or user interaction (PR:N/UI:N/AC:L). Limiting factors that reduce realistic risk: standalone (non-clustered) Fireboxes are not exposed via this path, and the cluster interconnect is typically a dedicated/isolated link, so the attacker must first obtain that adjacent network position. Complete fix is applying the vendor-updated Fireware OS (12.12.4, 2026.4, or 12.5.22 on the respective branches).

Impact

This is a genuine high-priority issue rather than a high-CVSS/low-real-risk case, though its exploitation is gated by network position. The input CVSS 4.0 vector (AV:A/AC:L/AT:N/PR:N/UI:N) describes an adjacent-network, low-complexity, unauthenticated attack with high confidentiality, integrity and availability impact to both the vulnerable and subsequent systems (VC/VI/VA:H, SC/SI/SA:H), consistent with a missing-authentication flaw (CWE-290) that yields root-level firewall management control. The vuln.today decision label is act_now and the vendor (WatchGuard) both reported the flaw and shipped a patch, which reinforces urgency. However, several widespread-exploitation signals are absent: this CVE is NOT listed in CISA KEV, no EPSS score is provided in the input, and no PoC or exploit reference is present, so there is no public exploit identified at time of analysis. The key tension is that the raw 9.4 score reflects root-level impact, but the AV:A vector means the attacker must already hold a privileged network position on the cluster interconnect - so real-world risk concentrates on environments running FireCluster high-availability pairs where the sync link or a peer could be reached or compromised, rather than on broad internet-facing exposure. Treat as act_now for FireCluster deployments; verify FireCluster usage before deprioritizing.

Exploit ScenarioDerived

An attacker who has compromised one node of a WatchGuard FireCluster high-availability pair, or who can intercept/inject traffic on the dedicated cluster interconnect link, sends a specially crafted FireCluster Sync request to a peer. Because the sync processing performs no authentication, the request is accepted and executes privileged firewall management actions as root. No public exploit code is identified at time of analysis, and the low attack complexity (AC:L) means no special timing or grooming is required once network position is obtained.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 28, 2026

Unauthenticated handling of FireCluster Sync traffic in WatchGuard Fireware OS lets an attacker who already holds a position on the cluster interconnect - a compromised cluster peer or an on-path attacker on the synchronization network - invoke privileged firewall management actions as root with a single crafted request, with no credentials or user interaction required. The flaw affects the Fireware OS 12.0 branch before 12.12.4, the 2025.1 branch before 2026.4, and the 12.0 branch before 12.5.22; Fireboxes that are not running FireCluster are not exposed through this path, which together with the typically isolated nature of the cluster interconnect is the main gating factor on real-world risk. Vendor patches are available on all three branches, and no public exploit code or CISA KEV entry was identified at time of analysis, though the vendor-reported CVSS of 9.4 and adjacent-network reachability warrant prompt remediation on clustered deployments.

RemediationAI

WatchGuard has released fixed Fireware OS builds on each affected branch: upgrade to 12.12.4 or later on the 12.0 train, to 2026.4 or later on the 2025.1 train, and to 12.5.22 or later on the corresponding 12.0 release line, following the vendor advisory at https://psirt.watchguard.com/CVE-2026-90465 for the exact build mapping before scheduling the update. Applying the vendor-updated firmware is the complete fix for the missing authentication in FireCluster Sync processing; until a cluster member is upgraded, that node retains the unauthenticated synchronization path. Because exploitation requires an attacker to already sit on the cluster interconnect, the practical interim control is to keep that interconnect on a dedicated, isolated segment that is not reachable from user, guest, WAN or general management networks, and to treat any compromised or untrusted cluster peer as an immediate exposure - removing an untrusted peer from the cluster eliminates the spoofing position the flaw depends on, at the cost of losing HA redundancy and requiring a re-sync when the peer is rebuilt. Standalone Fireboxes that do not run FireCluster are not exposed through this path and do not need emergency change handling for this specific issue.

Affected VersionsENISA

Fireware OS 12.0 <12.12.4
Fireware OS 2025.1 <2026.4
Fireware OS 12.0 <12.5.22

Affected Packages

euvd fireware_os fix: 12.5.22, 12.12.4, 2026.4

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Fireware OS is WatchGuard's firewall operating system, and FireCluster is its high-availability clustering feature, in which peer appliances synchronize state and configuration across a dedicated interconnect. CVE-2026-90465 is classified as CWE-290 (authentication bypass by spoofing), and the vendor describes the root cause as missing authentication in FireCluster Sync processing: synchronization requests are acted upon without verifying the identity of the sender, so anything able to deliver a crafted request on that path is treated as a trusted peer. The supplied CVSS:4.0 vector is AV:A/AC:L/AT:N/PR:N/UI:N with high confidentiality, integrity and availability impact to both the vulnerable system and subsequent systems (S:C), matching an adjacent-network attacker with no privileges who achieves root-level management capability. The precise request structure and the exact code path that fails to authenticate are not described in the available sources; what is confirmed is that the prerequisite is a running FireCluster deployment plus a foothold on the interconnect, not remote reachability from an arbitrary internet position. The CPE entries recorded for this CVE use unversioned wildcards for watchguard:fireware_os, so the authoritative version ranges come from the EUVD data rather than the CPE strings.

Know when Fireware Os gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (WatchGuard) PRIMARY 9.4 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 9.6 CRITICAL

Adjacent cluster-interconnect position gives AV:A; missing authentication gives PR:N and AC:L; root management control over the firewall and its protected traffic justifies S:C with C/I/A:H.

3.1 AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (WatchGuard).

CVSS VectorVendor: WatchGuard

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

Lifecycle Timeline

4
Patch available
Oct 27, 2026 - 17:18 EUVD
Severity Changed
Oct 27, 2026 - 16:22 NVD
HIGH CRITICAL
CVSS changed
Oct 27, 2026 - 16:22 NVD
8.7 (HIGH) 9.4 (CRITICAL)
CVE Published
Oct 27, 2026 - 15:52 cve.org
CRITICAL 9.4

DescriptionCVE.org

A missing authentication vulnerability in the FireCluster Sync processing allows an attacker positioned on the cluster interconnect, such as a compromised cluster peer or an on-path network attacker, to invoke privileged firewall management actions as root by sending a specially crafted request.

Executive ViewAI

Why It Matters

CVE-2026-90465 is a critical vulnerability in WatchGuard Fireware OS that allows an attacker with access to the cluster interconnect to execute privileged management actions as root without authentication. Organizations running FireCluster are at risk, but isolated cluster networks and the lack of public exploit code reduce the immediate threat. Leadership should prioritize patching clustered deployments to prevent potential compromise.

Business Impact: High
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
0.2%
Top 85% exploitable
Prevalence
Medium
WatchGuard Firebox is a common but mid-tier enterprise firewall appliance vendor
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.2%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
High

Priority Score

47
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +47
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

CVE-2026-103594 CRITICAL
9.5 Oct 27

Remote code execution and denial-of-service against WatchGuard Fireware OS 12.12 (before 12.12.4) and 2026.2 (before 202

CVE-2026-19313 CRITICAL
9.3 Aug 27

Remote code execution in WatchGuard Fireware OS is possible via a heap overflow (CWE-122) in the iked (IKE/IPsec key man

CVE-2026-19318 CRITICAL
9.3 Aug 27

Remote code execution in WatchGuard Fireware OS affects the iked (IKE/IPsec VPN key-exchange) daemon, where a stack-base

CVE-2026-19315 CRITICAL
9.3 Aug 27

Remote code execution in WatchGuard Fireware OS affects the iked IKE/IPsec VPN daemon, where a memory-safety defect lets

CVE-2026-13086 CRITICAL
9.3 Aug 27

Remote code execution in WatchGuard Fireware OS affects the epm (Endpoint Protection Manager) service tied to the deprec

CVE-2026-13368 CRITICAL
9.2 Jul 02

Remote code execution in WatchGuard Fireware OS affects Fireboxes running a Mobile User VPN with IKEv2 that authenticate

CVE-2026-93857 CRITICAL
9.2 Oct 27

Remote code execution in WatchGuard Fireware OS can be triggered by a crafted SIP request when the Firebox configuration

CVE-2026-93865 CRITICAL
9.2 Oct 27

Missing authentication in the Fireware OS FireCluster synchronization daemon lets remote, unauthenticated attackers invo

CVE-2026-93866 CRITICAL
9.2 Oct 27

Heap-based out-of-bounds write in WatchGuard Fireware OS Access Portal allows remote, unauthenticated attackers to corru

CVE-2026-112709 CRITICAL
9.2 Oct 27

Heap-based buffer overflow in the WatchGuard Fireware OS authentication service lets an attacker who controls or interce

CVE-2026-112710 CRITICAL
9.2 Oct 27

Heap-based buffer overflow in the WatchGuard Fireware OS authentication service can let an attacker who controls or inte

CVE-2026-86131 CRITICAL
9.2 Sep 29

Command injection as root in WatchGuard Fireware OS occurs through the BOVPN Over TLS client configuration handling, all

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy