Siemens SCALANCE EUVDEUVD-2025-209778

| CVE-2025-40833 HIGH
NULL Pointer Dereference (CWE-476)
2026-05-12 siemens GHSA-9483-pcvr-wj53
Denial Of Service Null Pointer Dereference Siemens Scalance X308 2M Sinamics G120C Sinamics G120D Sinamics G130 Sinamics G150 Sinamics S110 Sinamics S150 Ie Pb Link Ha Ie Pb Link Pn Io Ruggedcom Rm1224 Lte 4G Eu Ruggedcom Rm1224 Lte 4G Nam Scalance M804Pb Scalance M812 1 Adsl Router Scalance M816 1 Adsl Router Scalance M826 2 Shdsl Router Scalance M874 2 Scalance M874 3 Scalance M874 3 3G Router Cn Scalance M876 3 Scalance M876 3 Rok Scalance M876 4 Scalance M876 4 Eu Scalance M876 4 Nam Scalance Mub852 1 A1 Scalance Mub852 1 B1 Scalance Mum853 1 A1 Scalance Mum853 1 B1 Scalance Mum853 1 Eu Scalance Mum856 1 A1 Scalance Mum856 1 B1 Scalance Mum856 1 Cn Scalance Mum856 1 Eu Scalance Mum856 1 Row Scalance S615 Eec Lan Router Scalance S615 Lan Router Scalance Sc622 2C Scalance Sc626 2C Scalance Sc632 2C Scalance Sc636 2C Scalance Sc642 2C Scalance Sc646 2C Scalance W1748 1 M12 Scalance W1788 1 M12 Scalance W1788 2 Eec M12 Scalance W1788 2 M12 Scalance W1788 2Ia M12 Scalance W721 1 Rj45 Scalance W722 1 Rj45 Scalance W734 1 Rj45 Scalance W734 1 Rj45 Usa Scalance W738 1 M12 Scalance W748 1 M12 Scalance W748 1 Rj45 Scalance W761 1 Rj45 Scalance W774 1 M12 Eec Scalance W774 1 Rj45 Scalance W774 1 Rj45 Usa Scalance W778 1 M12 Scalance W778 1 M12 Eec Scalance W778 1 M12 Eec Usa Scalance W786 1 Rj45 Scalance W786 2 Rj45 Scalance W786 2 Sfp Scalance W786 2Ia Rj45 Scalance W788 1 M12 Scalance W788 1 Rj45 Scalance W788 2 M12 Scalance W788 2 M12 Eec Scalance W788 2 Rj45 Scalance Wab762 1 Scalance Wam763 1 Scalance Wam763 1 Me Scalance Wam763 1 Us Scalance Wam766 1 Scalance Wam766 1 Me Scalance Wam766 1 Us Scalance Wam766 1 Eec Scalance Wam766 1 Eec Me Scalance Wam766 1 Eec Us Scalance Wub762 1 Scalance Wub762 1 Ifeatures Scalance Wum763 1 Scalance Wum763 1 Us Scalance Wum766 1 Scalance Wum766 1 Me Scalance Wum766 1 Usa Scalance X204 2 Scalance X204 2Fm Scalance X204 2Ld Scalance X204 2Ld Ts Scalance X204 2Ts Scalance X206 1 Scalance X206 1Ld Scalance X208 Scalance X208Pro Scalance X212 2 Scalance X212 2Ld Scalance X216 Scalance X224 Scalance X302 7 Eec 230V Coated Scalance X302 7 Eec 230V Scalance X302 7 Eec 24V Coated Scalance X302 7 Eec 24V Scalance X302 7 Eec 2X 230V Coated Scalance X302 7 Eec 2X 230V Scalance X302 7 Eec 2X 24V Coated Scalance X302 7 Eec 2X 24V Scalance X304 2Fe Scalance X306 1Ld Fe Scalance X307 2 Eec 230V Coated Scalance X307 2 Eec 230V Scalance X307 2 Eec 24V Coated Scalance X307 2 Eec 24V Scalance X307 2 Eec 2X 230V Coated Scalance X307 2 Eec 2X 230V Scalance X307 2 Eec 2X 24V Coated Scalance X307 2 Eec 2X 24V Scalance X307 3 Scalance X307 3Ld Scalance X308 2 Scalance X308 2 Rd Inkl Siplus Variants Scalance X308 2Ld Scalance X308 2Lh Scalance X308 2M Poe Scalance X308 2M Ts Scalance X310 Scalance X310Fe Scalance X320 1 Fe Scalance X320 1 2Ld Fe Scalance X408 2 Scalance Xf204 Scalance Xf204 2 Scalance Xf206 1 Scalance Xf208 Scalance Xm408 4C Scalance Xm408 4C L3 Int Scalance Xm408 8C Scalance Xm408 8C L3 Int Scalance Xm416 4C Scalance Xm416 4C L3 Int Scalance Xr324 12M 230V Ports On Front Scalance Xr324 12M 230V Ports On Rear Scalance Xr324 12M 24V Ports On Front Scalance Xr324 12M 24V Ports On Rear Scalance Xr324 12M Ts 24V Scalance Xr324 4M Eec 100 240Vac 60 250Vdc Ports On Front Scalance Xr324 4M Eec 100 240Vac 60 250Vdc Ports On Rear Scalance Xr324 4M Eec 24V Ports On Front Scalance Xr324 4M Eec 24V Ports On Rear Scalance Xr324 4M Eec 2X 100 240Vac 60 250Vdc Ports On Front Scalance Xr324 4M Eec 2X 100 240Vac 60 250Vdc Ports On Rear Scalance Xr324 4M Eec 2X 24V Ports On Front Scalance Xr324 4M Eec 2X 24V Ports On Rear Scalance Xr324 4M Poe 230V Ports On Front Scalance Xr324 4M Poe 230V Ports On Rear Scalance Xr324 4M Poe 24V Ports On Front Scalance Xr324 4M Poe 24V Ports On Rear Scalance Xr324 4M Poe Ts 24V Ports On Front Scalance Xr524 8C 1X230V Scalance Xr524 8C 1X230V L3 Int Scalance Xr524 8C 24V Scalance Xr524 8C 24V L3 Int Scalance Xr524 8C 2X230V Scalance Xr524 8C 2X230V L3 Int Scalance Xr526 8C 1X230V Scalance Xr526 8C 1X230V L3 Int Scalance Xr526 8C 24V Scalance Xr526 8C 24V L3 Int Scalance Xr526 8C 2X230V Scalance Xr526 8C 2X230V L3 Int Scalance Xr528 6M Scalance Xr528 6M 2Hr2 L3 Int Scalance Xr528 6M 2Hr2 Scalance Xr528 6M L3 Int Scalance Xr552 12M Scalance Xr552 12M 2Hr2 L3 Int Scalance Xr552 12M 2Hr2 Simatic Cfu Diq Simatic Cfu Pa Simatic Et 200Pro Im 154 8 Pn Dp Cpu Simatic Et 200Pro Im 154 8F Pn Dp Cpu Simatic Et 200Pro Im 154 8Fx Pn Dp Cpu Simatic Et 200S Im 151 8 Pn Dp Cpu Simatic Et 200S Im 151 8F Pn Dp Cpu Simatic Et 200Sp Cpu 1510Sp F 1 Pn Simatic Et 200Sp Cpu 1510Sp 1 Pn Simatic Et 200Sp Cpu 1512Sp F 1 Pn Simatic Et 200Sp Cpu 1512Sp 1 Pn Simatic Et 200Sp Ha Im155 6 Pn Simatic S7 1500 Cpu 1511 1 Pn Simatic S7 1500 Cpu 1511F 1 Pn Simatic S7 1500 Cpu 1513 1 Pn Simatic S7 1500 Cpu 1515 2 Pn Simatic S7 1500 Cpu 1515F 2 Pn Simatic S7 1500 Cpu 1516 3 Pn Dp Simatic S7 1500 Cpu 1516F 3 Pn Dp Simatic S7 300 Cpu 314C 2 Pn Dp Simatic S7 300 Cpu 315 2 Pn Dp Simatic S7 300 Cpu 315F 2 Pn Dp Simatic S7 300 Cpu 315T 3 Pn Dp Simatic S7 300 Cpu 317 2 Pn Dp Simatic S7 300 Cpu 317F 2 Pn Dp Simatic S7 300 Cpu 317T 3 Pn Dp Simatic S7 300 Cpu 317Tf 3 Pn Dp Simatic S7 300 Cpu 319 3 Pn Dp Simatic S7 300 Cpu 319F 3 Pn Dp Simatic S7 400 Cpu 412 2 Pn V7 Simatic S7 400 Cpu 414 3 Pn Dp V7 Simatic S7 400 Cpu 414F 3 Pn Dp V7 Simatic S7 400 Cpu 416 3 Pn Dp V7 Simatic S7 400 Cpu 416F 3 Pn Dp V7 Simatic S7 400 H V6 Cpu Family Incl Siplus Variants Simatic S7 410 V10 Cpu Family Incl Siplus Variants Simatic S7 410 V8 Cpu Family Incl Siplus Variants Simit Unit V10 Simit Unit V11 Sinamics Cbe20 Sinamics G115D Sinamics G120 Incl Siplus Variants Sinamics G120X Sinamics G120Xa Sinamics S120 Incl Siplus Variants Sinumerik 840D Sl Siplus Et 200S Im 151 8 Pn Dp Cpu Siplus Et 200S Im 151 8F Pn Dp Cpu Siplus Net Ie Pb Link Pn Io Siplus S7 300 Cpu 314C 2 Pn Dp Siplus S7 300 Cpu 315 2 Pn Dp Siplus S7 300 Cpu 315F 2 Pn Dp Siplus S7 300 Cpu 317 2 Pn Dp Siplus S7 300 Cpu 317F 2 Pn Dp Siplus S7 400 Cpu 414 3 Pn Dp V7 Siplus S7 400 Cpu 416 3 Pn Dp V7 Sitop Psu8600 1Ac 20 A 4X5 A Pn Sitop Psu8600 3Ac 20 A Pn Sitop Psu8600 3Ac 20 A 4X5 A Pn Sitop Psu8600 3Ac 40 A Pn Sitop Psu8600 3Ac 40 A 4X10 A Pn Sitop Psu8600 3Ac 40 A 4X10A Eip Sitop Ups1600 10 A Ethernet Profinet Sitop Ups1600 20 A Ethernet Profinet Sitop Ups1600 40 A Ethernet Profinet Sitop Ups1600 Ex 20 A Ethernet Profinet
8.7
CVSS 4.0 · Vendor: siemens
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain network access to OT segment
  2. Delivery
    Craft malformed IPv4 packets
  3. Exploit
    Send to vulnerable Siemens device
  4. Execution
    Trigger null pointer dereference
  5. Impact
    Device crashes requiring manual restart

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A10:2025 - Mishandling of Exceptional Conditions
ASVS 5.0
V16 - Security Logging and Error Handling Null pointer safety, defensive checks
MITRE ATT&CK

1 technique across 1 tactic: Impact

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Remote network access to affected Siemens devices via IPv4 protocol - no authentication, user interaction, or non-default configuration required (AV:N/AC:L/PR:N/UI:N indicates exploitation against default configurations). Exploitation limited by network accessibility: devices on isolated OT networks behind firewalls or network segmentation require attacker presence on same network segment or compromise of adjacent systems. The low attack complexity suggests standard IPv4 packet crafting without protocol-specific exploitation techniques. Devices directly exposed to untrusted networks (internet, corporate IT networks without OT segmentation, vendor remote access connections) face immediate exploitation risk from remote unauthenticated attackers. Well-segmented industrial networks where affected devices communicate only with known automation systems via managed switches substantially reduce practical exploitability despite theoretical remote vector.

Impact

Real-world risk assessment presents a nuanced picture requiring careful evaluation. The CVSS 4.0 score of 8.7 primarily reflects maximum availability impact (VA:H) with an ideal attack vector (AV:N/AC:L/PR:N/UI:N), indicating remote unauthenticated denial of service. However, multiple mitigating factors temper urgency: no CISA KEV listing confirms active exploitation, no public proof-of-concept code exists, and EPSS data is not provided but likely low given the specialized industrial target environment. The SSVC framework suggests medium priority - while the vulnerability is technically exploitable remotely without authentication, the automatable aspect depends on network accessibility, and real-world OT environments typically implement defense-in-depth with network segmentation isolating industrial devices. The critical consideration is operational context: for facilities where affected SCALANCE switches provide primary network connectivity or SIMATIC PLCs control safety-critical processes, a denial-of-service requiring manual restart could cause production downtime or safety implications exceeding the pure technical severity. The 200+ affected product variants across PLCs, drives, switches, and routers indicate widespread deployment potential in manufacturing, energy, and critical infrastructure sectors. Priority should escalate for internet-exposed devices or environments lacking network segmentation, while well-segmented OT networks with compensating monitoring controls face lower immediate risk. The straightforward attack vector (crafted IPv4 packets) and lack of required privileges make automated scanning and exploitation plausible once attack details emerge.

Exploit ScenarioDerived

An attacker on the same network segment as vulnerable Siemens industrial devices crafts malicious IPv4 packets targeting the affected protocol stack implementation. The attacker sends these specially formatted packets to a SCALANCE switch providing connectivity for a manufacturing line or to a SIMATIC PLC controlling production equipment. The malformed IPv4 request triggers a null pointer dereference in packet processing code, causing immediate device crash and loss of network connectivity or control functionality. Affected devices require manual physical restart by operations personnel, resulting in unplanned production downtime.

Act Now Prioritize within 24-48h. Why: Active threat signals + CRITICAL/HIGH severity.
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – May 12, 2026

Denial of service in Siemens industrial networking equipment allows remote unauthenticated attackers to crash affected devices via specially crafted IPv4 packets, requiring manual restart for recovery. This vulnerability affects over 200 Siemens industrial automation products including SCALANCE switches/routers, SIMATIC PLCs, SINAMICS drives, and RUGGEDCOM devices. CVSS 4.0 score of 8.7 reflects high availability impact (VA:H) with network-accessible attack vector requiring low complexity and no privileges (AV:N/AC:L/PR:N). No public exploit code or CISA KEV listing identified at time of analysis, though the straightforward network-based attack and widespread product exposure warrant priority patching for operational technology environments where uptime is critical.

Earlier versions of this analysis (1)
v1 May 12, 2026 - 10:01 CVSS 7.5

Null pointer dereference in Siemens PROFINET devices allows remote unauthenticated denial of service via specially crafted IPv4 packets. Affects extensive portfolio of industrial networking equipment including SCALANCE switches/routers, RUGGEDCOM devices, SIMATIC PLCs, and SINAMICS drives. Crashed devices require manual restart, creating operational disruption risk in industrial control environments. CVSS 7.5 (High) with EPSS data unavailable - real-world impact depends on network segmentation and exposure of affected PROFINET infrastructure to untrusted networks.

RemediationAI

Apply vendor-released firmware updates per Siemens Security Advisory SSA-392349 available at https://cert-portal.siemens.com/productcert/html/ssa-392349.html. For SCALANCE networking products, upgrade to firmware version V8.3 or later (applies to M-series routers M804PB/M812/M816/M826/M874/M876/MUB/MUM, S615 routers, RUGGEDCOM RM1224). For SCALANCE W-series wireless access points, upgrade to V6.6.0 or later (W7xx models) or V3.2.0 or later (WAM7xx models). For SIMATIC S7-410 V10 CPU family, upgrade to firmware V10.2 or later. For SIMATIC ET 200SP HA IM155-6 PN, upgrade to V1.3 or later. For SIMATIC CFU devices, upgrade CFU DIQ and CFU PA to V2.0.0 or later. Many affected products (particularly older S7-300/400 CPUs, SINAMICS drives, and various SCALANCE X-series switches) show no upper version bound in EUVD data, indicating patches may not yet be available for all variants - consult Siemens advisory for product-specific remediation status. Compensating controls for unpatched devices: implement strict network segmentation isolating affected industrial devices from untrusted networks using firewalls or VLANs (reduces attack surface but requires network redesign and may complicate remote access), deploy intrusion detection systems monitoring for malformed IPv4 packets targeting affected devices (provides visibility but does not prevent exploitation), restrict IPv4 network access to affected devices using access control lists permitting only known-good IP addresses (effective for static environments but breaks dynamic manufacturing operations), and establish out-of-band management access for rapid recovery after denial-of-service events (mitigates impact of manual restart requirement but does not prevent downtime). Advisory recommends applying cell protection concept and defense-in-depth strategies per Siemens Industrial Security guidelines.

Affected VersionsENISA

SCALANCE X204-2 0 <*
SIMATIC ET 200SP CPU 1512SP F-1 PN 0 <*
SINAMICS G120D 0 <*
RUGGEDCOM RM1224 LTE(4G) NAM 0 <V8.3
SCALANCE X307-2 EEC (2x 24V, coated) 0 <*
SCALANCE WAM766-1 (US) 0 <V3.2.0
SIMATIC S7-300 CPU 315T-3 PN/DP 0 <*
SCALANCE W774-1 M12 EEC 0 <V6.6.0
SIMATIC S7-300 CPU 317F-2 PN/DP 0 <*
SIMATIC ET 200S IM 151-8F PN/DP CPU 0 <*
SIPLUS S7-400 CPU 416-3 PN/DP V7 0 <*
SCALANCE XR324-4M PoE (24V, ports on rear) 0 <*
SCALANCE X204-2TS 0 <*
SCALANCE WAM766-1 (ME) 0 <V3.2.0
SINAMICS S150 0 <*
SIMATIC S7-400 CPU 414F-3 PN/DP V7 0 <*
SIPLUS S7-300 CPU 314C-2 PN/DP 0 <*
SCALANCE WAM763-1 (ME) 0 <V3.2.0
SCALANCE X408-2 0 <*
SCALANCE S615 LAN-Router 0 <V8.3
SCALANCE M874-3 3G-Router (CN) 0 <V8.3
SCALANCE XR552-12M (2HR2) 0 <*
SCALANCE X308-2LD 0 <*
RUGGEDCOM RM1224 LTE(4G) EU 0 <V8.3
SCALANCE XM408-8C 0 <*
SCALANCE WAM766-1 EEC (ME) 0 <V3.2.0
SCALANCE XR528-6M (2HR2, L3 int.) 0 <*
SCALANCE W774-1 RJ45 (USA) 0 <V6.6.0
SIMATIC S7-400 CPU 412-2 PN V7 0 <*
SCALANCE MUB852-1 (A1) 0 <V8.3
SCALANCE SC622-2C 0 <*
SIMATIC S7-300 CPU 317T-3 PN/DP 0 <*
SCALANCE X307-3LD 0 <*
SINAMICS CBE20 0 <*
SCALANCE WUM766-1 (USA) 0 <V3.2.0
SCALANCE X308-2LH 0 <*
SIMIT UNIT V11 0 <*
SCALANCE X320-1-2LD FE 0 <*
SCALANCE MUM853-1 (EU) 0 <V8.3
SCALANCE W1748-1 M12 0 <*
SCALANCE XR524-8C, 1x230V 0 <*
SCALANCE WUB762-1 0 <V3.2.0
SCALANCE X302-7 EEC (24V, coated) 0 <*
SITOP PSU8600 3AC 20 A PN 0 <*
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) 0 <*
SCALANCE SC626-2C 0 <*
SIMATIC CFU DIQ 0 <V2.0.0
SCALANCE XR526-8C, 1x230V 0 <*
SITOP UPS1600 40 A Ethernet/ PROFINET 0 <*
SITOP UPS1600 10 A Ethernet/ PROFINET 0 <*
SCALANCE XR524-8C, 2x230V (L3 int.) 0 <*
SCALANCE W748-1 RJ45 0 <V6.6.0
SCALANCE XR528-6M (2HR2) 0 <*
SIPLUS ET 200S IM 151-8 PN/DP CPU 0 <*
SCALANCE X216 0 <*
SINAMICS G130 0 <*
SCALANCE X308-2M PoE 0 <*
SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) 0 <*
SCALANCE X320-1 FE 0 <*
SINAMICS G115D 0 <*
SIMATIC ET 200SP CPU 1512SP-1 PN 0 <*
SCALANCE MUM853-1 (A1) 0 <V8.3
SCALANCE W1788-2 M12 0 <*
SCALANCE W778-1 M12 EEC (USA) 0 <V6.6.0
SCALANCE X204-2FM 0 <*
SIMATIC S7-300 CPU 314C-2 PN/DP 0 <*
SCALANCE SC646-2C 0 <*
SCALANCE XF206-1 0 <*
SINAMICS G120XA 0 <*
SIMATIC S7-1500 CPU 1515-2 PN 0 <*
SCALANCE M812-1 ADSL-Router 0 <V8.3
SCALANCE X212-2 0 <*
SCALANCE W761-1 RJ45 0 <V6.6.0
SCALANCE X302-7 EEC (2x 230V) 0 <*
SCALANCE WUB762-1 iFeatures 0 <V3.2.0
SCALANCE W734-1 RJ45 0 <V6.6.0
SCALANCE X308-2M 0 <*
SCALANCE WAM763-1 0 <V3.2.0
SIMATIC S7-300 CPU 319-3 PN/DP 0 <*
SIPLUS S7-400 CPU 414-3 PN/DP V7 0 <*
SITOP PSU8600 1AC 20 A/4x5 A PN 0 <*
SCALANCE M876-3 0 <V8.3
SCALANCE M876-4 0 <V8.3
SIMATIC S7-1500 CPU 1516F-3 PN/DP 0 <*
SCALANCE WUM766-1 0 <V3.2.0
SIMATIC S7-300 CPU 317-2 PN/DP 0 <*
SCALANCE XR552-12M 0 <*
SIMATIC S7-1500 CPU 1511F-1 PN 0 <*
SCALANCE W778-1 M12 EEC 0 <V6.6.0
SCALANCE X302-7 EEC (2x 230V, coated) 0 <*
SIMATIC S7-300 CPU 315F-2 PN/DP 0 <*
SCALANCE WAM766-1 EEC 0 <V3.2.0
SCALANCE XR324-12M (230V, ports on front) 0 <*
SIMATIC CFU PA 0 <V2.0.0
SCALANCE XR552-12M (2HR2, L3 int.) 0 <*
SCALANCE X307-3 0 <*
SIMATIC S7-1500 CPU 1513-1 PN 0 <*
SCALANCE X308-2LH+ 0 <*
SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) 0 <V8.3
SCALANCE W734-1 RJ45 (USA) 0 <V6.6.0
SCALANCE XM408-4C 0 <*
SCALANCE X308-2 RD (inkl. SIPLUS variants) 0 <*
SCALANCE X306-1LD FE 0 <*
SCALANCE XR324-4M PoE (230V, ports on front) 0 <*
SITOP PSU8600 3AC 40 A/4x10A EIP 0 <*
SCALANCE W788-2 M12 EEC 0 <V6.6.0
SCALANCE X204-2LD 0 <*
SCALANCE WAM766-1 0 <V3.2.0
SCALANCE M874-2 0 <V8.3
SCALANCE W788-2 M12 0 <V6.6.0
SCALANCE XR324-12M (24V, ports on rear) 0 <*
SCALANCE X204-2LD TS 0 <*
SIMATIC ET 200pro IM 154-8FX PN/DP CPU 0 <*
SCALANCE X302-7 EEC (2x 24V) 0 <*
SITOP UPS1600 EX 20 A Ethernet PROFINET 0 <*
SINAMICS G120X 0 <*
SIPLUS ET 200S IM 151-8F PN/DP CPU 0 <*
SCALANCE X307-2 EEC (230V) 0 <*
SCALANCE X208 0 <*
SCALANCE XR526-8C, 2x230V 0 <*
SCALANCE WAB762-1 0 <V3.2.0
SCALANCE X307-2 EEC (2x 230V, coated) 0 <*
SCALANCE X302-7 EEC (230V, coated) 0 <*
SCALANCE SC636-2C 0 <*
SCALANCE MUM856-1 (B1) 0 <V8.3
SCALANCE XR524-8C, 2x230V 0 <*
SIMATIC S7-300 CPU 319F-3 PN/DP 0 <*
SCALANCE W786-1 RJ45 0 <V6.6.0
SCALANCE X302-7 EEC (230V) 0 <*
SCALANCE XR324-4M EEC (24V, ports on front) 0 <*
SIPLUS S7-300 CPU 315F-2 PN/DP 0 <*
SCALANCE M804PB 0 <V8.3
SCALANCE WAM763-1 (US) 0 <V3.2.0
SCALANCE W1788-1 M12 0 <*
SIMATIC ET 200SP HA IM155-6 PN 0 <V1.3
SINAMICS G120C 0 <*
SCALANCE XR324-12M (24V, ports on front) 0 <*
SINAMICS S120 (incl. SIPLUS variants) 0 <*
SITOP PSU8600 3AC 20 A/4x5 A PN 0 <*
SIMATIC S7-1500 CPU 1515F-2 PN 0 <*
SCALANCE X206-1 0 <*
SCALANCE X304-2FE 0 <*
SCALANCE W788-1 M12 0 <V6.6.0
SCALANCE XR524-8C, 1x230V (L3 int.) 0 <*
SCALANCE M876-4 (NAM) 0 <V8.3
SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) 0 <*
SIMATIC S7-400 CPU 416F-3 PN/DP V7 0 <*
SCALANCE XM416-4C 0 <*
SCALANCE MUB852-1 (B1) 0 <V8.3
SCALANCE M874-3 0 <V8.3
SIMATIC ET 200pro IM 154-8F PN/DP CPU 0 <*
SCALANCE W774-1 RJ45 0 <V6.6.0
SIMATIC ET 200pro IM 154-8 PN/DP CPU 0 <*
SIMATIC S7-300 CPU 317TF-3 PN/DP 0 <*
SCALANCE MUM856-1 (EU) 0 <V8.3
SCALANCE W788-1 RJ45 0 <V6.6.0
SIMATIC S7-1500 CPU 1511-1 PN 0 <*
SIMATIC S7-400 CPU 416-3 PN/DP V7 0 <*
SCALANCE M826-2 SHDSL-Router 0 <V8.3
SCALANCE XR324-4M EEC (24V, ports on rear) 0 <*
SINAMICS G120 (incl. SIPLUS variants) 0 <*
SIPLUS S7-300 CPU 317-2 PN/DP 0 <*
SCALANCE X307-2 EEC (24V) 0 <*
SITOP PSU8600 3AC 40 A PN 0 <*
SCALANCE XF204-2 0 <*
SCALANCE X308-2M TS 0 <*
SCALANCE XR528-6M (L3 int.) 0 <*
SCALANCE M876-3 (ROK) 0 <V8.3
SINUMERIK 840D sl 0 <*
SCALANCE W786-2 SFP 0 <V6.6.0
SIMATIC S7-300 CPU 315-2 PN/DP 0 <*
SCALANCE X308-2 0 <*
SCALANCE M876-4 (EU) 0 <V8.3
SCALANCE X307-2 EEC (2x 24V) 0 <*
SCALANCE XR324-4M PoE TS (24V, ports on front) 0 <*
SIMATIC S7-1500 CPU 1516-3 PN/DP 0 <*
SCALANCE XF204 0 <*
SCALANCE W722-1 RJ45 0 <V6.6.0
SCALANCE X224 0 <*
SCALANCE XR528-6M 0 <*
SCALANCE SC632-2C 0 <*
SCALANCE WUM766-1 (ME) 0 <V3.2.0
SCALANCE XR324-12M (230V, ports on rear) 0 <*
SCALANCE W786-2 RJ45 0 <V6.6.0
SCALANCE W1788-2IA M12 0 <*
IE/PB link PN IO 0 <*
SCALANCE W748-1 M12 0 <V6.6.0
SCALANCE XR324-4M EEC (2x 24V, ports on rear) 0 <*
SCALANCE MUM856-1 (RoW) 0 <V8.3
SIPLUS S7-300 CPU 315-2 PN/DP 0 <*
SCALANCE XF208 0 <*
SIMATIC S7-400 CPU 414-3 PN/DP V7 0 <*
SCALANCE WUM763-1 0 <V3.2.0
SIMATIC ET 200S IM 151-8 PN/DP CPU 0 <*
SCALANCE W738-1 M12 0 <V6.6.0
SCALANCE MUM856-1 (CN) 0 <V8.3
SCALANCE M816-1 ADSL-Router 0 <V8.3
SCALANCE XR526-8C, 1x230V (L3 int.) 0 <*
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) 0 <*
SIMATIC ET 200SP CPU 1510SP F-1 PN 0 <*
SIMIT UNIT V10 0 <*
SCALANCE XR324-4M PoE (230V, ports on rear) 0 <*
SCALANCE XR324-4M PoE (24V, ports on front) 0 <*
SCALANCE XR524-8C, 24V (L3 int.) 0 <*
SCALANCE MUM853-1 (B1) 0 <V8.3
SCALANCE X302-7 EEC (24V) 0 <*
SCALANCE X307-2 EEC (24V, coated) 0 <*
SCALANCE XR324-4M EEC (2x 24V, ports on front) 0 <*
IE/PB LINK HA 0 <*
SCALANCE XR526-8C, 2x230V (L3 int.) 0 <*
SCALANCE W1788-2 EEC M12 0 <*
SCALANCE X206-1LD 0 <*
SCALANCE X212-2LD 0 <*
SCALANCE XR526-8C, 24V 0 <*
SIMATIC ET 200SP CPU 1510SP-1 PN 0 <*
SCALANCE XR526-8C, 24V (L3 int.) 0 <*
SCALANCE XM416-4C (L3 int.) 0 <*
SCALANCE W786-2IA RJ45 0 <V6.6.0
SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) 0 <*
SCALANCE WUM763-1 (US) 0 <V3.2.0
SITOP UPS1600 20 A Ethernet/ PROFINET 0 <*
SCALANCE S615 EEC LAN-Router 0 <V8.3
SCALANCE WAM766-1 EEC (US) 0 <V3.2.0
SIPLUS S7-300 CPU 317F-2 PN/DP 0 <*
SCALANCE X310 0 <*
SCALANCE MUM856-1 (A1) 0 <V8.3
SCALANCE SC642-2C 0 <*
SCALANCE W778-1 M12 0 <V6.6.0
SCALANCE X208PRO 0 <*
SCALANCE W721-1 RJ45 0 <V6.6.0
SCALANCE X302-7 EEC (2x 24V, coated) 0 <*
SCALANCE X310FE 0 <*
SCALANCE XR524-8C, 24V 0 <*
SCALANCE W788-2 RJ45 0 <V6.6.0
SINAMICS G150 0 <*
SCALANCE XR324-12M TS (24V) 0 <*
SITOP PSU8600 3AC 40 A/4x10 A PN 0 <*
SCALANCE XM408-8C (L3 int.) 0 <*
SCALANCE XM408-4C (L3 int.) 0 <*
SCALANCE X307-2 EEC (2x 230V) 0 <*
SINAMICS S110 0 <*
SCALANCE X307-2 EEC (230V, coated) 0 <*
SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) 0 <V10.2
SIPLUS NET IE/PB link PN IO 0 <*

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability stems from a null pointer dereference (CWE-476) in IPv4 packet processing code shared across Siemens industrial automation platforms. The affected CPE strings span SCALANCE industrial Ethernet switches (M-series routers, X-series switches, W-series wireless), SIMATIC programmable logic controllers (S7-300/400/1500 series CPUs), SINAMICS motor drives (G120/G130/S120/S150), RUGGEDCOM ruggedized networking equipment, IE/PB communication links, and SITOP industrial power supplies with embedded networking. A null pointer dereference occurs when software attempts to access memory through a pointer that has not been properly initialized or validated, causing immediate process termination. In network protocol stacks, this typically happens when malformed packets trigger edge cases in parsing logic where expected data structures are absent. The vulnerability affects firmware versions prior to V8.3 in networking products and unpatched versions across the PLC/drive product lines, suggesting a common networking stack component shared across Siemens industrial portfolio. The network-accessible nature (AV:N) and lack of authentication requirement (PR:N) make this particularly concerning for industrial control systems that often have limited segmentation.

Know when Scalance X308 2M gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 8.7 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens) · only source for this CVE.

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
None
Vulnerable system: Integrity
None
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

3
Analysis Updated
May 12, 2026 - 10:40 vuln.today
v2 - CVSS changed
CVSS changed
May 12, 2026 - 10:22 NVD
7.5 (HIGH) 8.7 (HIGH)
CVE Published
May 12, 2026 - 08:20 nvd
HIGH 7.5

DescriptionCVE.org

The affected devices contain a null pointer dereference vulnerability while processing specially crafted IPv4 requests. This could allow an attacker to cause denial of service condition. A manual restart is required to recover the system.

Executive ViewAI

Why It Matters

CVE-2025-40833 is a high-severity denial-of-service vulnerability affecting over 200 Siemens industrial automation products (SCALANCE, SIMATIC, SINAMICS, RUGGEDCOM) that allows unauthenticated remote attackers to crash devices via malformed network packets, requiring manual restart for recovery. Organizations operating Siemens industrial control systems face potential production downtime and safety risks until mitigations are deployed, as affected devices are network-accessible without authentication requirements.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: (1) Implement network-based ingress filtering and rate-limiting on firewall/IDS to block malformed IPv4 packets before reaching industrial devices; (2) Isolate affected Siemens devices on segmented OT networks with restricted external connectivity; (3) Deploy network anomaly detection tuned to industrial protocols; (4) Establish rapid device restart procedures and redundant control system configurations where operationally feasible to minimize uptime impact; (5) Monitor Siemens security advisories for patch releases and vendor-provided technical guidance on packet signatures/blocking rules.

Threat Intelligence Overview

EPSS Score
0.0%
Top 88% exploitable
Threat Intel
1
1 source
Data Quality
7 sources
Confidence: High
EUVD NVD CVE.org EPSS Vulnrichment CISA VulDB

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.0%
Patch available No
Active threat Yes
Deciding rule
Active threat signals + CRITICAL/HIGH severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
Yes
Human Impact
High
Technical Impact
Partial

Priority Score

54
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: +10
Gov advisory: 0

Attack Technique

A null pointer dereference occurs when a program attempts to access memory through a pointer that has been set to NULL (address 0x0).

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

Threat IntelligenceMISP

CISA Advisories
Sources: CISA (public domain)

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy