Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Input neutralization, injection prevention
|
| Impact | Full system compromise — the attacker can execute any command with the privileges of the vulnerable application process. With a CVSS score of 6.3 (MEDIUM), this represents a moderate risk. |
| Exploit ScenarioDerived | An attacker injects shell metacharacters (;, |, &&) into a parameter that is passed to a system command, causing additional commands to be executed. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 14, 2026
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Earlier versions of this analysis (1)
RemediationAI
Avoid passing user input to system commands. Use language-specific APIs instead of shell commands. If unavoidable, use strict input validation and escaping.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Command injection allows an attacker to execute arbitrary OS commands on the host system through a vulnerable application that passes user input to system shells.
Know when Ac18 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2Executive ViewAI
Organizations using A vulnerability should be aware of moderate risk from CVE-2025-5606, a injection vulnerability rated CVSS 6.3. Exploitation could allow attackers to execute code or inject malicious input. Proof-of-concept code is publicly available. Organizations should apply vendor updates when available and monitor for exploitation.
Apply vendor patch. If patching is delayed: deploy WAF rules, restrict network access, enable logging.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
More in Ac18 Firmware
View allTenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload func
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Rated critical severity (CVSS 9.8), thi
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. Rated
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Rated critic
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Rat
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName paramet
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Rated critical severity (CVSS 9.8
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime fu
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Rated critical severity (CV
EUVD-2025-16911
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB