Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain physical access to camera
-
DeliveryConnect to debug/UART interface
-
ExploitInterrupt normal boot process
-
ExecutionEnter unauthenticated bootloader console
-
ImpactInspect or modify firmware and boot config
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication required for critical functions
MITRE ATT&CK
1 technique across 1 tactic: Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires physical access to the device and a physical connection to its debug interface (e.g., UART/JTAG serial console); the attacker must interrupt the normal boot sequence to reach the interactive bootloader, which then requires no authentication (PR:N) and no user interaction (UI:N). Exploitation is strictly LIMITED by the Physical attack vector (AV:P) - there is no network or local-OS remote path - so realistic risk is confined to scenarios of device theft, supply-chain tampering, or unsupervised physical placement of the camera. Affected firmware is HMT.CM2507 v251211.1507 on the CareCam CM2507 camera. |
| Impact | This is a low real-world priority despite being a genuine missing-authentication weakness (CWE-306). The vendor CVSS 3.1 vector CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N yields a base of 3.5 (Low), driven almost entirely by the Physical attack vector (AV:P) - the interactive bootloader is only reachable through a physical debug interface (UART/JTAG-style header), so no remote or network exploitation is possible. There is no EPSS score, no CISA KEV listing, and no public exploit code identified at time of analysis, all consistent with the low severity. The only aggravating signals are AC:L (once physical access is obtained, interrupting the boot process is trivial) and PR:N/UI:N (no credentials or user interaction needed at the console). No conflicting signals: the network-independent nature of the flaw is coherent across the description, the CWE, and the AV:P vector. Bottom line - a legitimate hardware-hardening gap that matters only to attackers who already have the device in hand. |
| Exploit ScenarioDerived | An attacker who physically possesses or can open a CM2507 IP camera connects to the exposed debug interface, interrupts the normal boot sequence, and drops into the unauthenticated bootloader console. From there they inspect or alter boot configuration, dump or modify firmware, and load unauthorized software onto the device. No public exploit code is required or identified - the interface simply grants console access once physical connection is made. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Sep 18, 2026
Physical access to a CareCam CM2507 IP camera running firmware HMT.CM2507 v251211.1507 lets an attacker connect to an unauthenticated debug interface, interrupt the normal boot sequence, and reach an interactive bootloader that can inspect or modify boot configuration, firmware data, and loaded software. The weakness requires hands-on access and a physical connection to the device's debug port, so exploitation is confined to scenarios such as device theft, supply-chain tampering, or unsupervised physical placement. It carries a low CVSS base score of 3.5, no public exploit code has been identified at time of analysis, and no CISA KEV listing or EPSS score was provided in the available intelligence.
RemediationAI
No vendor-released patch version is specified in the available intelligence, so the first step is to consult CISA ICS advisory ICSA-26-258-08 (https://www.cisa.gov/news-events/ics-advisories/icsa-26-258-08) and the matching CSAF record (https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-258-08.json) for any firmware update or vendor-issued mitigation. Where the firmware supports it, disable or permanently lock the physical debug interface and enable secure boot or signed firmware so that interrupting the boot sequence cannot drop into an unauthenticated interactive bootloader; the trade-off is that locking the interface or blowing security fuses removes field-recovery and laboratory debugging options and can turn a recoverable device into a brick if a firmware update fails. Compensating controls should focus on the physical attack vector: restrict the CM2507 to physically controlled, supervised locations, use tamper-evident seals or enclosure monitoring to detect hardware access, and apply supply-chain verification for cameras that may have been intercepted or left unattended, accepting that these are detective rather than preventive measures. Actions such as network segmentation or firewall rules do not address this flaw, since the assessed vector is AV:P and the attack path does not traverse the network.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-306 (Missing Authentication for Critical Function): the CM2507 firmware HMT.CM2507 v251211.1507 leaves an interactive bootloader reachable through a physical debug interface, typically a UART or JTAG header on the board, without any authentication, challenge, or signed-boot gate before the bootloader becomes interactive. Because the bootloader loads and can modify boot configuration, firmware data, and the software the device then runs, an attacker who interrupts the boot process at the right moment gains low-level control over the device's initialization and code path. The assessed CVSS:3.1 vector AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N confirms that no credentials (PR:N) and no user interaction (UI:N) are needed, but the Physical attack vector (AV:P) means there is no network or local OS remote path; confidentiality and integrity impacts are limited (C:L/I:L) and availability is not affected (A:N), which is consistent with a constrained, hardware-tethered attack surface rather than a remotely exploitable flaw. The CPE cpe:2.3:a:carecam:hmt.cm2507_firmware:*:*:*:*:*:*:*:* identifies the affected software as the vendor's camera firmware line, and the ICS-CERT/CISA advisory ICSA-26-258-08 is the authoritative source for affected versions and any vendor guidance.
Know when Hmt Cm2507 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
Bootloader reachable only via physical debug port (AV:P), trivially entered once connected (AC:L) with no auth (PR:N); boot-config/firmware read and modify give limited C:L and I:L, no availability impact.
Primary rating from Vendor (icscert).
CVSS VectorVendor: icscert
Lifecycle Timeline
1DescriptionCVE.org
A CM2507 IP camera running firmware version HMT.CM2507 v251211.1507 exposes an interactive bootloader through a physical debug interface without requiring authentication. An attacker with physical access could interrupt the normal boot process and access functionality that permits inspection or modification of boot configuration, firmware data, and software loaded by the device.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
More in Hmt Cm2507 Firmware
View allCareCam CM2507 IP cameras running firmware v251211.1507 store the root account password as a fixed, legacy hash that off
Cleartext storage of wireless network credentials in CM2507 IP cameras running HMT.CM2507 firmware v251211.1507 lets any
Unauthenticated access to the network video streaming service in CareCam CM2507 (HMT CM2507) IP cameras exposes live cam
CM2507 IP cameras expose a privileged ONVIF management account that accepts an empty password, allowing anyone who can r
Physical-access arbitrary code execution on Carecam HMT.CM2507 IP cameras, where firmware automatically runs a predeterm
CareCam CM2507 IP cameras expose an insufficiently protected network maintenance mechanism that can activate a remote de
EUVD-2026-83046
GHSA-98v9-gfg6-qq55
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB