Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Network-accessible CIP interface, no auth or interaction required, crash-only impact maps to A:H with unchanged scope.
Primary rating from Vendor (rockwellautomation).
CVSS VectorVendor: rockwellautomation
Lifecycle Timeline
2DescriptionCVE.org
A denial-of-service security issue exists in the affected product. The security issue stems from a crafted CIP packet being sent crashing the module. The device requires a restart to recover.
AnalysisAI
Denial-of-service in a Rockwell Automation industrial module allows unauthenticated remote attackers to crash the device by sending a single crafted CIP (Common Industrial Protocol) packet, requiring a manual restart to restore availability. The vulnerability affects operational technology (OT) environments where CIP is network-accessible, making it particularly dangerous in industrial control system (ICS) contexts where device downtime can disrupt physical processes. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | No authentication is required (PR:N in CVSS 4.0 vector) and no special configuration of the target device is needed - any module instance that accepts CIP traffic over the network is exploitable. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 4.0 score of 8.7 accurately reflects a high-impact, low-barrier network DoS against an industrial device. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | Full exploit scenario with step-by-step reproduction available after sign-in. |
| Remediation | Consult Rockwell Automation security advisory SD1798 at https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1798.html for the exact patched firmware version and upgrade instructions; a vendor-released patch is available per the advisory, but the specific fix version is not confirmed in the provided CVE data. … Detailed patch versions, workarounds, and compensating controls in full report. |
Recommended ActionAI
Within 24 hours: Identify all Rockwell Automation industrial modules in your environment and assess their network exposure; immediately apply network segmentation to restrict CIP (Common Industrial Protocol) access to only authorized systems. …
Sign in for detailed remediation steps and compensating controls.
Threat intelligence, references, and detailed analysis are available after sign-in.
Same weakness CWE-400 – Uncontrolled Resource Consumption
View allSame technique Denial Of Service
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-69127
GHSA-vgg9-hj2v-mg26