Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach router web UI over network
-
DeliverySend crafted request to /goform/ate
-
ExploitBypass missing authentication check
-
ExecutionInvoke privileged ate functionality
-
ImpactReconfigure or compromise device
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication required for critical functions
MITRE ATT&CK
1 technique across 1 tactic: Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | No credentials or user interaction are required - R7WebsSecurityHandler omits the authentication check on the /goform/ate endpoint, so any request reaching that path on Tenda AC1206 firmware 15.03.06.23 is processed as if authorized. The concrete prerequisite is network reachability to the device's HTTP web-UI service. The key limiting factor is exposure: SOHO router admin interfaces are typically LAN-bound, so practical exploitation generally requires an attacker on the local/Wi-Fi network unless WAN-side remote management is enabled, in which case it becomes internet-reachable. Confirmed affected build is 15.03.06.23; behavior on other firmware versions is unverified. |
| Impact | The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N with high vulnerable- and subsequent-system impact) describes an easy, unauthenticated, network-reachable bug, and publicly available exploit code raises practical risk. However, several tempering signals apply: this is a VulDB-sourced disclosure for a consumer router, there is no CISA KEV listing (no confirmed active exploitation) and no EPSS probability was supplied, so evidence of real-world mass exploitation is currently absent. The most important real-world limiter is exposure surface - SOHO router web UIs are normally bound to the LAN, so 'remote' realistically means same-network (or WAN-exposed only where remote management is enabled), which meaningfully narrows the attack population versus an internet-facing service. The subsequent-system impact metrics (SC/SI/SA:H) in the supplied 4.0 vector look optimistic for a self-contained device compromise and should be treated with caution. Net assessment: a genuinely serious, easy-to-exploit flaw for anyone able to reach the device's web interface, warranting prompt patching where these routers are deployed, but not clearly a widespread internet-wide emergency absent KEV/EPSS corroboration. |
| Exploit ScenarioDerived | An attacker with reachability to the router's web interface (a malicious client on the LAN/Wi-Fi, or the internet if remote management is enabled) sends a crafted HTTP request directly to /goform/ate, which R7WebsSecurityHandler serves without checking authentication. Because public exploit code exists and attack complexity is low, the attacker invokes the exposed factory/diagnostic functionality to reconfigure or take control of the device with no credentials. This requires no user interaction and no prior authentication. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Aug 31, 2026
Missing authentication in the Tenda AC1206 (firmware 15.03.06.23) lets remote attackers reach the /goform/ate endpoint of the web UI without any credentials because the R7WebsSecurityHandler function fails to enforce access control. Any attacker with network reachability to the device's web interface can invoke the protected functionality directly, and publicly available exploit code exists. This is a VulDB-reported issue with a CVSS 4.0 base score of 9.3; it is not listed in CISA KEV and no EPSS score was provided.
Earlier versions of this analysis (1)
Authentication bypass in the Tenda AC1206 router (firmware 15.03.06.23) lets remote attackers reach the /goform/ate ATE endpoint without credentials because the R7WebsSecurityHandler function fails to enforce authentication (CWE-306). Publicly available exploit code exists, and the flaw is remotely reachable against default configurations, giving unauthenticated attackers privileged access to the device's web management interface.
RemediationAI
No vendor-released patch or fixed firmware version is identified at time of analysis, and no fixed build is cited in the references. As compensating controls: disable remote (WAN-side) web management on the device so /goform/ate cannot be reached from the internet - this is the highest-value mitigation and has minimal downside for typical users; restrict access to the router's HTTP administration interface to a trusted management VLAN or specific admin hosts via ACLs, accepting that legitimate admins must connect from those segments; and place the device behind a firewall that blocks inbound access to its web UI port from untrusted networks. Segment untrusted/guest Wi-Fi clients away from the router management interface to limit LAN-side abuse. Monitor the Tenda advisory channel (https://www.tenda.com.cn/) and https://vuldb.com/cve/CVE-2026-82694 for a firmware update and apply it once released. If the device is end-of-life or no fix appears, plan replacement.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected component is the embedded HTTP server (goform-based web UI) running on the Tenda AC1206 SOHO Wi-Fi router. R7WebsSecurityHandler is the routine intended to gate access to administrative endpoints; the flaw is that it does not require authentication for the /goform/ate handler, exposing it to anonymous callers. This maps to CWE-306 (Missing Authentication for a Critical Function): a sensitive endpoint is reachable without any credential check. The 'ate' handler in Tenda/Broadcom-lineage firmware is typically an Automated-Test-Equipment/factory-diagnostic interface, which commonly exposes powerful device-control or debug operations that should never be reachable post-manufacture. The single affected CPE is cpe:2.3:a:tenda:ac1206:*:*:*:*:*:*:*:* at firmware 15.03.06.23.
Know when Ac1206 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P
Unauthenticated network-reachable endpoint with no auth check gives PR:N/UI:N/AC:L; full device control yields C/I/A:H; impact confined to the device so S:U.
Primary rating from Vendor (VulDB).
CVSS VectorVendor: VulDB
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability was identified in Tenda AC1206 15.03.06.23. This issue affects the function R7WebsSecurityHandler of the file /goform/ate of the component Web UI. The manipulation leads to missing authentication. The attack can be initiated remotely. The exploit is publicly available and might be used.
Technical POC Analysis
Bug class: CWE-306, Missing Authentication for Critical Function.
Full technical POC analysis - root cause, step-by-step exploitation and patch breakdown - is part of the Pro and Business plans.
Latest POC
1 public PoC link from github
Sign in to open the public PoC links collected for this CVE.
Executive ViewAI
Tenda AC1206 routers running firmware 15.03.06.23 contain a critical authentication bypass allowing unauthenticated remote attackers to execute protected administrative functions without credentials. With publicly available exploit code and no vendor patch available, all deployed instances with network access face immediate exploitation risk.
Restrict firewall access to web management ports (TCP 80/443) to trusted administrative networks only; disable remote management and WAN access features; implement network segmentation to isolate affected devices from critical systems; enable device logging for /goform/ate endpoint access attempts; deploy intrusion detection rules for exploitation patterns; monitor for vendor patches weekly.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Authentication bypass in the Tenda AC1206 router (firmware 15.03.06.23) lets remote, unauthenticated attackers reach the
Stack-based buffer overflow in Tenda AC1206 firmware 15.03.06.23_multi_TD01 exposes the router's web management interfac
Stack-based buffer overflow in the Tenda AC1206 router firmware 15.03.06.23_multi_TD01 allows a remotely authenticated a
EUVD-2026-68507
GHSA-79rc-8x3p-4wjw
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB