Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessSend HTTP request to configuration endpoint
-
DeliveryEmbed CRLF sequences in config parameter
-
ExploitTrigger config file write
-
ExecutionInject arbitrary configuration directives
-
PersistCorrupt system settings
-
ImpactDegrade device integrity or availability
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization CRLF sequence sanitization
|
| Exploitation Conditions | The vulnerability requires network-accessible SD-330AC or AMC Manager with default or exposed configuration endpoints. CRLF injection succeeds when the device processes configuration data in text-based formats (such as INI, conf, or text-delimited files) without filtering CR and LF characters. Exploitation is not limited by platform type, specific firmware version, or non-default configuration-the wildcard version specification in CPE indicates all released versions are affected. The attack does not require user interaction (UI:N) or authentication (PR:N), meaning attackers do not need valid credentials or victim involvement. Limiting factors: devices isolated behind firewalls or network segmentation blocking unauthorized configuration requests are protected from remote exploitation. Local administrative access to the device file system can directly modify configuration, but this is a separate attack path. The vulnerability is specific to configuration processing; other functionality (if isolated from configuration injection) may not be impacted. |
| Impact | This vulnerability presents significant real-world risk despite a moderate CVSS score of 6.5. The network attack vector (AV:N), low complexity (AC:L), and lack of authentication requirement (PR:N/UI:N) indicate broad exploitability against default configurations. The integrity impact (I:L) and availability impact (A:L) reflect the practical consequence: injected configuration entries can disable features, redirect traffic, or degrade service. The CVSS score omits confidentiality impact (C:N), suggesting information disclosure is not a direct concern, but configuration tampering can indirectly expose sensitive data through misconfigured access controls. The JPCERT disclosure and vendor advisories confirm active awareness in the security community; however, EPSS exploitation probability and KEV (CISA Known Exploited Vulnerabilities) status are not provided in the input data. The scope is unchanged (S:U), limiting cross-boundary impact, but the attack requires no interaction and succeeds over unauthenticated network access, making this a high-priority issue for organizations deploying Silex storage infrastructure in accessible network segments. |
| Exploit ScenarioDerived | An attacker on the network sends a crafted HTTP or API request to the SD-330AC or AMC Manager configuration endpoint, embedding CRLF sequences in a parameter field (e.g., a device name, DNS setting, or access control list entry). The application parses the input without sanitization and writes it directly to the system configuration file. The injected line breaks cause the parser to interpret subsequent attacker-controlled text as new configuration directives, such as disabling authentication, modifying network routes, or changing access permissions. The attacker gains control over device behavior without authentication or user interaction. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Apr 20, 2026
CRLF injection in Silex Technology SD-330AC and AMC Manager allows unauthenticated remote attackers to inject arbitrary configuration entries via crafted input, degrading system integrity and availability. The vulnerability affects all versions of both products and requires no authentication or user interaction, with public disclosure through JPCERT and vendor advisories indicating elevated awareness in production environments.
RemediationAI
Check the Silex Technology security advisories (https://www.silex.jp/support/security-advisories/en/2026-001) for patched versions specific to your SD-330AC and AMC Manager installations, as exact fix versions are not provided in available data. Apply vendor-released patches or firmware updates immediately upon availability. Immediate compensating controls include: restrict network access to SD-330AC and AMC Manager administrative interfaces using network segmentation or firewall rules-only permit configuration access from trusted management subnets, disabling internet-facing exposure of these services. Disable remote configuration APIs if not required for operational workflows, reducing the attack surface. Implement input validation or Web Application Firewall (WAF) rules to block requests containing CRLF sequences (%0D%0A, carriage return, line feed characters) in configuration parameters, though this may block legitimate but unusual configuration patterns. Monitor system configuration files for unauthorized modifications using file integrity monitoring (FIM) tools, alerting on unexpected changes to device settings. These controls mitigate the immediate risk while patch availability is confirmed.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
CRLF (Carriage Return/Line Feed) injection exploits improper neutralization of sequence characters (CWE-93) in configuration processing pipelines. When user-supplied input is embedded directly into configuration files or system settings without sanitization, attackers can inject CR (\r) and LF (\n) characters to break line boundaries and insert malicious configuration directives. The SD-330AC is a network storage device and AMC Manager is its administrative interface; both parse configuration data in text-based formats vulnerable to line-boundary manipulation. The attack leverages the network-accessible configuration endpoints of these devices to corrupt system state without requiring prior authentication.
Know when Amc Manager gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2DescriptionCVE.org
SD-330AC and AMC Manager provided by silex technology, Inc. contain an improper neutralization of CRLF sequences ('CRLF Injection') vulnerability. Processing some crafted configuration data may lead to arbitrary entries injected to the system configuration.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Code injection occurs when an application accepts user input and passes it directly into a language interpreter or evaluator without proper sanitization.
EUVD-2026-23757
GHSA-5f3w-cmwx-c9m9
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB