Skip to main content

IBM AIX CVE-2026-16932

| EUVDEUVD-2026-63389 HIGH
OS Command Injection (CWE-78)
2026-08-20 ibm GHSA-26qm-x758-cmmx
8.8
CVSS 3.1 · Vendor: ibm
Share

Severity by source

Vendor (ibm) PRIMARY
8.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
vuln.today AI
8.8 HIGH

Local low-privilege access suffices to set ODMDIR; scope change reflects privileged ODM-dependent system components executing injected commands, warranting full C/I/A.

3.1 AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
4.0 AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (ibm).

CVSS VectorVendor: ibm

Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Analysis Generated
Aug 20, 2026 - 15:36 vuln.today
CVE Published
Aug 20, 2026 - 14:39 nvd
HIGH 8.8

DescriptionCVE.org

IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to execute arbitrary commands due to improper validation of the ODMDIR environment variable.

AnalysisAI

Arbitrary OS command execution via ODMDIR environment variable manipulation affects IBM AIX 7.2 and 7.3 and PowerVM VIOS 4.1, enabling local authenticated users to escalate privileges beyond their initial access boundary. The CVSS scope change (S:C) indicates that successful exploitation can compromise components outside the immediate process context - a critical concern for AIX systems hosting sensitive workloads. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires a local user account with at least standard (low) privileges - confirmed by CVSS PR:L. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 8.8 score accurately reflects a serious local privilege escalation: AV:L confirms exploitation requires local access, PR:L means any standard user account suffices, AC:L indicates no special timing or race conditions are needed, and S:C with full C:H/I:H/A:H means the attacker can achieve complete system compromise including potential hypervisor-layer impact via PowerVM VIOS. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation IBM has released a patch available through the IBM support portal at https://www.ibm.com/support/pages/node/7283858; administrators should apply the vendor-supplied fix immediately. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, inventory all IBM AIX 7.2, 7.3, and PowerVM VIOS 4.1 systems and obtain the available vendor patch from IBM's support portal. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

More in Aix

View all
CVE-2013-4011 HIGH POC
7.2 Jul 18

Multiple unspecified vulnerabilities in the InfiniBand subsystem in IBM AIX 6.1 and 7.1, and VIOS 2.2.2.2-FP-26 SP-02, a

CVE-2023-28528 HIGH POC
7.8 Apr 28

IBM AIX 7.1, 7.2, 7.3, and VIOS 3.1 could allow a non-privileged local user to exploit a vulnerability in the invscout c

CVE-2016-3053 HIGH POC
7.8 Feb 01

IBM AIX contains an unspecified vulnerability that would allow a locally authenticated user to obtain root level privile

CVE-2016-6079 HIGH POC
7.8 Feb 15

IBM AIX 5.3, 6.1, 7.1, and 7.2 contains an unspecified vulnerability that would allow a locally authenticated user to ob

CVE-2016-8972 HIGH POC
7.8 Feb 15

IBM AIX 6.1, 7.1, and 7.2 could allow a local user to gain root privileges using a specially crafted command within the

CVE-2014-8904 HIGH POC
7.2 Jan 15

lquerylv in cmdlvm in IBM AIX 5.3, 6.1, and 7.1 and VIOS 2.2.x allows local users to gain privileges via a crafted DBGCM

CVE-2012-2179 MEDIUM POC
6.9 Jun 22

libodm.a in IBM AIX 5.3, 6.1, and 7.1 allows local users to overwrite arbitrary files via a symlink attack on a temporar

CVE-2014-3977 MEDIUM POC
6.9 Jun 08

libodm.a in IBM AIX 6.1 and 7.1, and VIOS 2.2.x, allows local users to overwrite arbitrary files via a symlink attack on

CVE-2026-18835 CRITICAL
9.9 Aug 20

OS command injection in IBM AIX 7.2 and 7.3 and PowerVM VIOS 4.1 lets a remote, low-privileged authenticated attacker ru

CVE-2026-16816 CRITICAL
9.9 Aug 19

OS command injection in IBM AIX 7.2 and 7.3 and in IBM PowerVM VIOS 4.1 lets a remote, authenticated attacker execute ar

CVE-2026-15068 CRITICAL
9.9 Aug 19

OS command injection in IBM AIX 7.2/7.3 and PowerVM VIOS 4.1 lets a remote authenticated attacker run arbitrary commands

CVE-2024-56346 CRITICAL
10.0 Mar 18

IBM AIX 7.2 and 7.3 nimesis NIM master service could allow a remote attacker to execute arbitrary commands due to improp

Share

CVE-2026-16932 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy