Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAttacker gains low-privileged network access
-
DeliveryCrafts malicious CSRF payload page
-
ExploitDelivers phishing link to authenticated FDS 102 operator
-
ExecutionVictim's browser loads attacker page
-
PersistForged HTTP request sent to FDS 102 with victim credentials
-
ImpactUnintended diagnostic or configuration action executed
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V3 - Web Frontend Security Anti-CSRF tokens, SameSite cookies
MITRE ATT&CK
1 technique across 1 tactic: Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | The attack requires three concurrent conditions: first, the victim must hold an active authenticated session to the FDS 102 web interface (the CVSS 4.0 PR:L metric also indicates the attacker requires low-privileged standing, though the exact nature of that privilege is not specified in available data); second, the victim must be induced to visit an attacker-controlled web page while their FDS 102 session remains active (UI:P - requires user interaction, the primary limiting factor for mass exploitation); third, the FDS 102 web interface must be network-reachable from the victim's browser (AV:N). Exploitation is bounded by the social engineering dependency: this is not a drive-by or automated attack vector. Default-configured instances of the FDS 102 web interface within their affected version range are susceptible, as no special non-default feature flag or configuration appears required beyond having the web interface enabled. |
| Impact | The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N) indicates a network-reachable attack with low complexity, no attack requirements, low attacker privileges, and a single user interaction (the victim visiting a malicious page). High impact across confidentiality, integrity, and availability of the vulnerable system further elevates the score to 8.6. The PR:L metric is notable: it implies the attacker must hold some form of low-privileged standing in the environment - not an entirely unauthenticated external threat actor. UI:P introduces a dependency on social engineering or phishing to induce the authenticated victim to visit the attacker-controlled page, which somewhat constrains opportunistic mass exploitation. No CISA KEV listing and no known public exploit code reduce immediate urgency for most organizations; however, the industrial railway deployment context means successful exploitation of 'unintended actions' could affect safety-critical operations, and the absence of KEV does not imply this is low risk in OT environments. EPSS data is not available in provided intelligence; exploitation probability cannot be quantified from current inputs. |
| Exploit ScenarioDerived | An attacker with low-privileged network presence crafts a malicious HTML page containing a hidden cross-origin form or JavaScript fetch that submits a state-changing request to the FDS 102 web interface. The attacker delivers a link to this page - via phishing email, compromised intranet resource, or injected content - to an FDS 102 operator who is currently authenticated. When the operator's browser loads the malicious page, their session credentials are automatically included in the forged request, causing the FDS 102 to execute the attacker-chosen action (e.g., modifying sensor configuration or diagnostic parameters) without the operator's knowledge or consent. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Aug 20, 2026
CSRF in the Frauscher FDS 102 web interface (versions 2.0.0 through 2.13.3) allows a low-privileged remote attacker to coerce authenticated users into executing unintended actions by directing them to a crafted malicious web page. The CVSS 4.0 score of 8.6 reflects high confidentiality, integrity, and availability impact against the vulnerable system, driven by the absence of complexity requirements and the low privilege bar for the attacker. No public exploit code or CISA KEV listing has been identified at time of analysis, though the industrial railway context of this product elevates operational risk if exploited.
RemediationAI
Consult the CERTVDE advisory VDE-2026-078 at https://www.certvde.com/en/advisories/VDE-2026-078/ for vendor-issued guidance; an exact patched release version is not confirmed from the available intelligence data, so the advisory should be treated as the authoritative source for upgrade targets. As a compensating control while awaiting patching, restrict access to the FDS 102 web interface to only trusted, isolated network segments (e.g., a dedicated OT VLAN with no internet-facing exposure), which reduces attacker ability to deliver the malicious page to a user in the same browser session. Additionally, user awareness training specific to OT operators - emphasizing not opening external links or web pages while authenticated to industrial web interfaces - directly targets the UI:P prerequisite. Disabling the FDS web interface entirely and relying on alternative management channels, if operationally feasible, eliminates the attack surface at the cost of losing web-based diagnostic access.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
CWE-352 (Cross-Site Request Forgery) describes a failure in which a web application trusts requests that originate from an authenticated user's browser without verifying that the user intentionally initiated them. The affected product, identified by CPE cpe:2.3:a:frauscher_sensortechnik:fds_102:*:*:*:*:*:*:*:*, is the Frauscher Diagnostic System 102 - an industrial field diagnostic platform used in railway infrastructure, manufactured by Frauscher Sensortechnik. Its web interface does not implement adequate CSRF token validation or origin-checking mechanisms, meaning a malicious third-party web page can issue authenticated HTTP requests to the FDS 102 on behalf of a logged-in user. Because the target is an industrial control system web interface rather than a general-purpose web application, the potential operational consequences of unauthorized actions extend to safety-critical sensor configuration or diagnostic commands.
Know when Fds 102 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Network vector for web-accessible interface; PR:L per 'low privileged attacker' description; UI:R as victim must visit malicious page; scope unchanged as impact stays within FDS application boundary.
Primary rating from Vendor (CERTVDE).
CVSS VectorVendor: CERTVDE
DescriptionCVE.org
An low privileged remote attacker can cause authenticated users to perform unintended actions in the FDS Web interface using malicious web pages.
Executive ViewAI
Frauscher FDS 102 web interfaces controlling railway signaling systems (versions 2.0.0-2.13.3) contain an unpatched CVSS 8.6 CSRF vulnerability capable of enabling unauthorized manipulation of train control operations through authenticated operator hijacking; no public exploit identified at time of analysis. The absence of vendor remediation creates operational risk beyond standard patch management, requiring network-level compensating controls to protect critical railway infrastructure.
Implement network-based access controls to restrict FDS 102 web interface to trusted IP ranges; deploy Web Application Firewall (WAF) rules enforcing SameSite cookie attributes and CSRF token validation; require re-authentication for sensitive administrative actions; place systems behind a bastion host with multi-factor authentication; monitor access logs for suspicious cross-origin requests and unusual operator actions; establish operator training on phishing and social engineering tactics; disable or restrict non-essential web-based operator access when not actively required.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Cross-Site Request Forgery exploits the automatic credential inclusion behavior of web browsers.
Session fixation/expiration weakness in the Frauscher Sensortechnik FDS 102 web interface (versions 2.1.0 through 2.13.3
Unauthenticated file disclosure in the Frauscher FDS 102 Field Detection System web interface exposes sensitive railway
Zip-slip path traversal in Frauscher FDS 102 enables a high-privileged remote attacker to overwrite arbitrary files on t
Session hijacking in Frauscher Sensortechnik FDS 102 versions 2.13.0 through 2.13.3 allows a remote attacker with a low-
Remote code execution is achievable on the Frauscher FDS 102 field data server when a high-privileged attacker uploads a
Privilege escalation in Frauscher FDS 102 (versions 2.11.0 through 2.13.3) allows a low-privileged authenticated attacke
User enumeration in the Frauscher FDS 102 railway diagnostic system allows low-privileged remote attackers to retrieve t
EUVD-2026-63222
GHSA-hcc2-q42w-v7pc
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB