Skip to main content

Spacelabs Sentinel CVE-2026-0611

| EUVDEUVD-2026-33974 CRITICAL
Missing Authentication for Critical Function (CWE-306)
2026-06-02 VulnCheck GHSA-344f-p6q5-rw6q
9.2
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Recon
    Identify Sentinel host with TCP/8989 reachable
  2. Delivery
    Send crafted .NET Remoting URI request
  3. Exploit
    Invoke unauthenticated file-write primitive
  4. Install
    Drop ASPX webshell into IIS wwwroot
  5. C2
    Request webshell URL over HTTP
  6. Execute
    Execute commands as IIS app pool
  7. Impact
    Access cardiology data and pivot

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication required for critical functions
MITRE ATT&CK

1 technique across 1 tactic: Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

The vulnerable .NET Remoting HTTP channel on TCP/8989 must be network-reachable to the attacker, which per the description is NOT the case in a default Sentinel installation - exploitation specifically requires that port 8989 has been deliberately made network-accessible through configuration changes or permissive firewall/network policy. The Sentinel installation must be version 10.5.x or higher in the 10.x line, or any 11.x build prior to 11.6.0. The attacker must be able to issue HTTP requests to port 8989 (so attacker must be on a network path that reaches it - internet, clinical LAN, or VPN). No authentication is required (PR:N), no user interaction is required (UI:N), and attack complexity is low (AC:L). The principal limiting factor reducing real-world exposure is the non-default port exposure (reflected as AT:P in the CVSS 4.0 vector); sites that never exposed port 8989 are not exploitable over the network even on vulnerable versions.

Impact

The CVSS 4.0 score of 9.2 with vector AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H reflects network reachability, low complexity, no privileges, and no user interaction, with full confidentiality, integrity, and availability impact on the vulnerable component - and crucially the AT:P (Attack Requirements: Present) bit acknowledges the non-default configuration prerequisite. EPSS and KEV data are not provided in the input, so probabilistic exploitation likelihood and CISA active-exploitation status are unknown at time of analysis. No public exploit identified at time of analysis, though VulnCheck (the reporter) has published an advisory that may contain technical detail enabling rapid weaponization. Real-world risk is bimodal: for Sentinel deployments where port 8989 has been intentionally exposed (e.g., for legacy integrations or misconfigured network segmentation), this is a critical priority due to unauthenticated RCE in a clinical system; for default deployments the immediate internet-facing exposure is limited, but internal-network attackers who reach the segment can still exploit it trivially.

Exploit ScenarioDerived

An attacker with network reach to a Sentinel server that has had TCP/8989 explicitly exposed (for example, through a misconfigured firewall rule or an integration the customer deliberately enabled) sends a crafted .NET Remoting request specifying a URI endpoint that invokes the file-write primitive, dropping an ASPX webshell into the IIS wwwroot directory. The attacker then requests the webshell over HTTP, causing IIS to compile and execute it under the application pool identity, yielding interactive command execution on a clinical system that holds patient cardiology data. No public exploit identified at time of analysis, but the technique (writing .aspx via arbitrary-file-write to achieve RCE) is well-documented and likely to be reproduced quickly from VulnCheck's advisory.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Jun 02, 2026

Unauthenticated remote code execution in Spacelabs Healthcare Sentinel (versions 10.5.x and 11.x prior to 11.6.0) allows network attackers to drop ASPX webshells into the IIS wwwroot via a legacy .NET Remoting HTTP channel on TCP/8989. The flaw stems from missing authentication (CWE-306) on a deprecated Microsoft remoting endpoint, and while a vendor patch is available, no public exploit identified at time of analysis. Exploitation requires that port 8989 has been deliberately exposed to the network, since it is not reachable in default Sentinel deployments.

RemediationAI

Vendor-released patch: upgrade Sentinel to version 11.6.0 or later per Spacelabs Security Advisory 079-0273-00 RevA (https://spacelabshealthcare.com/wp-content/uploads/2026/06/079-0273-00-RevA-Security-Advisory-Sentinel-.NET-Remoting-Vulnerability.pdf); the 10.5.x and earlier 11.x branches do not appear to receive a backported fix, so upgrade is the only sanctioned remediation. If immediate patching is not possible, block TCP/8989 at the host firewall and any upstream network ACL - because port 8989 is not used in default Sentinel installations, blocking it should have no impact on standard clinical workflow, though sites that previously exposed it for a custom .NET Remoting integration will lose that integration and must validate with the integration owner before blocking. Additionally, segment the Sentinel server into a restricted clinical VLAN with allowlisted source IPs for management traffic, and audit IIS wwwroot for unexpected .aspx files as a compromise check before and after remediation. Consult VulnCheck's advisory at https://www.vulncheck.com/advisories/spacelabs-healthcare-sentinel-x-unauthenticated-rce-via-net-remoting for additional detection guidance.

Affected VersionsENISA

Sentinel 10.5.0 <11.6.0

Affected Packages

euvd sentinel fix: 11.6.0

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Sentinel is Spacelabs Healthcare's diagnostic cardiology connectivity platform, used in clinical environments to manage Holter and ambulatory ECG data. The vulnerable component is a .NET Remoting HTTP channel - a legacy Microsoft inter-process communication framework that Microsoft itself deprecated and warned against exposing to untrusted networks because it lacks built-in authentication and deserializes attacker-controlled object graphs. The CWE-306 (Missing Authentication for Critical Function) classification is precise here: the remoting endpoint on port 8989 accepts arbitrary .NET URI endpoint requests without identity verification, and the implementation exposes file read and write primitives that can be aimed at the IIS web root co-hosted on the same machine. Writing an .aspx file into wwwroot causes ASP.NET to compile and execute it on the next HTTP request, converting an arbitrary-file-write primitive into full RCE under the IIS application pool identity.

Know when Sentinel gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 9.2 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (VulnCheck) · only source for this CVE.

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
Present
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

1
CVSS changed
Jun 02, 2026 - 17:22 NVD
9.8 (CRITICAL) 9.2 (CRITICAL)

DescriptionCVE.org

Spacelabs Healthcare Sentinel versions 10.5.x and higher and 11.x.x before 11.6.0 contain an unauthenticated remote code execution vulnerability through a deprecated .NET Remoting HTTP channel exposed on port 8989 that allows attackers to perform arbitrary file read and write operations by supplying valid .NET URI endpoints. Attackers can write ASPX webshells to the IIS wwwroot directory to achieve unauthenticated remote code execution on the system. Port 8989 is not exposed in a default Sentinel installation; exploitation requires that the .NET Remoting port has been explicitly made network-accessible through deliberate configuration or network policy changes.

Executive ViewAI

Why It Matters

Spacelabs Healthcare Sentinel versions prior to 11.6.0 contain a critical unauthenticated vulnerability allowing remote code execution if port 8989 is network-accessible. Healthcare organizations relying on Sentinel for patient monitoring face operational disruption, data breaches, and care delivery impact if affected systems are exposed.

Business Impact: Severe
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
0.2%
Top 59% exploitable
Social Media
1
Sightings
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.2%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Out-of-Cycle
Exploitation
Poc
System Exposure· derived
Open
Automatable
Yes
Human Impact
Very High
Technical Impact
Total

Priority Score

46
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +46
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2017-12821 CRITICAL
9.8 Oct 04

Memory corruption in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55

CVE-2017-12822 CRITICAL
9.9 Oct 04

Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Se

CVE-2017-12819 CRITICAL
9.8 Oct 04

Remote manipulations with language pack updater lead to NTLM-relay attack for system user in Gemalto's HASP SRM, Sentine

CVE-2017-12818 HIGH
7.5 Oct 04

Stack overflow in custom XML-parser in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK

CVE-2017-12820 HIGH
7.5 Oct 04

Arbitrary memory read from controlled memory pointer in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prio

CVE-2017-5185 HIGH
7.5 Mar 30

A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow remote denial of service. Rated

CVE-2014-3460 MEDIUM
6.8 May 20

Directory traversal vulnerability in the DumpToFile method in the NQMcsVarSet ActiveX control in Agent Manager in NetIQ

CVE-2016-1605 MEDIUM
6.5 Aug 01

Directory traversal vulnerability in the ReportViewServlet servlet in the server in NetIQ Sentinel 7.4.x before 7.4.2 al

CVE-2017-5184 MEDIUM
5.3 Mar 30

A vulnerability was discovered in NetIQ Sentinel Server 8.0 before 8.0.1 that may allow leakage of information (account

CVE-2018-7675 MEDIUM
5.3 Mar 07

In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. Rated medium severity (CVSS 5

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy